Evaluación de la profundidad de curado en resinas Bulk Fill de alta y mediana densidad polimerizadas con lámparas de fotocurado multi-onda y mono-onda
dc.contributor.advisor | Luna Ángel, Luis Eduardo | |
dc.contributor.advisor | Tamayo Muñoz, Martha Cecilia | |
dc.contributor.advisor | Díaz Báez, David Augusto | |
dc.contributor.author | Chávez Bravo, Andrea Esthefania | |
dc.contributor.author | Navarro Carrillo, Heydi Yulieth | |
dc.contributor.orcid | Chávez Bravo, Andrea Esthefania | |
dc.date.accessioned | 2023-08-11T22:21:54Z | |
dc.date.available | 2023-08-11T22:21:54Z | |
dc.date.issued | 2023 | |
dc.description.abstract | Antecedentes: La eficacia clínica de las resinas Bulk Fill en cavidades clase I y II cuya profundidad aproximada es de 5mm, está determinada por la densidad de la resina – alta o mediana, y el tipo de onda de la luz emitida por la lámpara de fotocurado -onda única o de onda múltiple, sin embargo, la evaluación del efecto sobre la profundidad de curado de estos dos factores combinados, aún no ha sido realizada. Objetivo: Evaluar la profundidad de curado en resinas Bulk fill de alta y mediana densidad polimerizadas con lámparas multi onda y mono onda a 0 y 5 mm. Métodos: En este estudio experimental in vitro se utilizó una muestra probabilística por grupo de 20 discos de resina. Se evaluaron dos tipos de resina de alta densidad (Tetric EvoCeram Bulk Fill® y la Filtek™ One Bulk Fill Restorative) y dos tipos de resina de mediana densidad (Filtek™ Bulk Fill Flowable Restorative 3 y Opus Bulk Fill Flow APS) las cuales fueron polimerizadas con dos tipos de lámpara; multi onda (Bluephase N de Ivoclar Vivadent) y mono onda (Elipar Deepcure de 3M); para un total de 8 grupos. La dureza shore se evaluó a 0 y 5 mm mediante un durómetro Shore calibrado. Los datos se reportaron en dureza shore a dichas profundidades y para determinar la profundidad de curado se calculó la proporción entre la dureza shore a 5 mm con respecto a la obtenida a 0mm. Los datos fueron analizados con las pruebas de Kruskal Wallis y Post-Hoc de Dunn (p>0.05). Resultados: Al analizar la dureza shore a 0 y 5 mm no se presentaron diferencias estadísticamente significativas entre las resinas de alta y media densidad (0mm = p > 0,0687 y 5mm = p > 0.0656), sin embargo, si se presentaron al comparar las lámparas de fotocurado entre sí (0mm = p < 0. 000 y 5mm = p > 0.0205) observándose una dureza shore para la lámpara multi-onda (0mm = Me:95.5-RIQ:92.5–97.5 y 5mm = Me:92-RIQ:89 – 94). Al evaluar la profundidad de curado, se observaron diferencias estadísticamente significativas entre ambas resinas (p < 0.0147) y entre las dos lámparas evaluadas (p < 0.0001) observándose un mayor valor para la resina de media densidad (Me:96.81%-RIQ:95.85–96.91) y para la lámpara mono-onda (Me:96.81%-RIQ:96.81–97.85) Conclusiones: Dentro de los límites de este estudio se puede concluir que tanto las resinas de alta como mediana densidad fotopolimerizadas con lámparas mult-ionda y mono- onda pueden ser usadas con confiablidad en la restauración de cavidades clase I y II dado que los datos de profundidad de curado fueron mayores a 80% tal y como lo sugiere la norma ISO 868 de 2003. | spa |
dc.description.abstractenglish | Background: Clinical efficiency of bulk-fill resins in class I and II cavities of approximately 5mm depth is determined by its high or medium density and light-wave type. However, curing depth effect regarding these factors has not been evaluated so far. Objective: to evaluate curing depth of said resins and lamps at 0 mm and 5 mm. Methods: This in vitro experimental study was composed of 20 resin discs with two high-density types (Tetric EvoCeram Bulk Fill® and Filtek™ One Bulk Fill Restorative) and two medium-density types (Filtek™ Bulk Fill Flowable Restorative 3 and Opus Bulk Fill Flow APS) which were polymerized with two lamp types: poly-wave (Bluephase-N from Ivoclar Vivadent) and mono-wave (Elipar Deepcure -3M) for a total of eight groups. The shore hardness was evaluated at 0 mm and 5 mm with a calibrated shore durometer with data was reported and their proportion used to determine depth. Data was analysed with the Kruskal Wallis and Dunn´s post hoc test (p>0.05). Results: No significant hardness differences were found between resins (0mm = p > 0,0687 and 5mm = p > 0.0656), there were differences between lamps (0mm = p < 0. 000 and 5mm = p > 0.0205) of a shore hardness for the poly-wave lamp (0mm = Me:95.5-RIQ:92.5–97.5 and 5mm = Me:92-RIQ:89 – 94). Further significant differences were observed in the curing depths between resins (p < 0.0147) and lamps (p < 0.0001) where the medium-density obtained a higher value (Me:96.81%-RIQ:95.85–96.91) as well as the mono-wave (Me:96.81%-RIQ:96.81–97.85) Conclusions: it may be concluded that the evaluated resins and lamps may be reliably used for class I and II cavity restorations given that curing depth were above 80% as suggested by ISO 868 of 2003. | eng |
dc.description.degreelevel | Especialización | spa |
dc.description.degreename | Especialista en prostodoncia | spa |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | instname:Universidad El Bosque | spa |
dc.identifier.reponame | reponame:Repositorio Institucional Universidad El Bosque | spa |
dc.identifier.repourl | repourl:https://repositorio.unbosque.edu.co | |
dc.identifier.uri | https://hdl.handle.net/20.500.12495/11272 | |
dc.language.iso | spa | |
dc.publisher.faculty | Facultad de Odontología | spa |
dc.publisher.grantor | Universidad El Bosque | spa |
dc.publisher.program | Especialización en prostodoncia | spa |
dc.rights | Atribución-NoComercial-CompartirIgual 4.0 Internacional | * |
dc.rights.accessrights | https://purl.org/coar/access_right/c_abf2 | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.local | Acceso abierto | spa |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | * |
dc.subject | Resinas bulk fill alta densidad | spa |
dc.subject | Resinas bulk fill mediana densidad | spa |
dc.subject | Lámparas de fotopolimerización multi onda | spa |
dc.subject | Lámparas de fotopolimerización mono onda | spa |
dc.subject | Dureza shore | spa |
dc.subject.keywords | High density bulk fill resins | eng |
dc.subject.keywords | Medium density bulk fill resins | eng |
dc.subject.keywords | Multi-wave curing lights | eng |
dc.subject.keywords | Mono-wave curing lights | eng |
dc.subject.keywords | Shore hardness | eng |
dc.subject.nlm | WU 500 | |
dc.title | Evaluación de la profundidad de curado en resinas Bulk Fill de alta y mediana densidad polimerizadas con lámparas de fotocurado multi-onda y mono-onda | spa |
dc.title.translated | Evaluation of curing depth of Bulk-Fill high and medium density resins polymerised with poly-wave and mono-wave photocuring lamps | eng |
dc.type.coar | https://purl.org/coar/resource_type/c_7a1f | |
dc.type.coarversion | https://purl.org/coar/version/c_970fb48d4fbd8a85 | |
dc.type.driver | info:eu-repo/semantics/bachelorThesis | |
dc.type.hasversion | info:eu-repo/semantics/acceptedVersion | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Especialización | spa |
Archivos
Bloque original
1 - 2 de 2
Cargando...
- Nombre:
- Evaluación de la profundidad de curado en resinas Bulk Fill de alta y mediana densidad polimerizadas con lámparas de fotocurado multi-onda y mono-onda
- Tamaño:
- 1.68 MB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Evaluación de la profundidad de curado en resinas Bulk Fill de alta y mediana densidad polimerizadas con lámparas de fotocurado multi-onda y mono-onda
No hay miniatura disponible
- Nombre:
- Referencias bibliográficas
- Tamaño:
- 22.19 KB
- Formato:
- Microsoft Word XML
- Descripción:
- Referencias bibliográficas
Bloque de licencias
1 - 4 de 4
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 1.95 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción:
No hay miniatura disponible
- Nombre:
- Carta.pdf
- Tamaño:
- 1.03 MB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Carta de autorización
No hay miniatura disponible
- Nombre:
- Carta2.pdf
- Tamaño:
- 996.33 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Anexo
No hay miniatura disponible
- Nombre:
- Acta.pdf
- Tamaño:
- 140.54 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Acta