Tecnologías existentes y emergentes para el monitoreo terapéutico del litio: una revisión panorámica

dc.contributor.advisorPedraza Sanabria, Santiago
dc.contributor.advisorWhittingham Valero, Karen Vanessa
dc.contributor.advisorGiraldo-Cadavid, Luis Fernando
dc.contributor.advisorBustos, Rosa Helena
dc.contributor.advisorPrieto, Lina
dc.contributor.advisorSeetal, Dodd
dc.contributor.orcidPedraza Sanabria, Santiago [0009-0004-8900-4880]spa
dc.date.accessioned2023-12-05T12:59:47Z
dc.date.available2023-12-05T12:59:47Z
dc.date.issued2023
dc.description.abstractEl litio tiene un margen terapéutico estrecho. Su Monitoreo Terapéutico de Medicamento (TDM) tiene varias barreras. Objetivos: Esta revisión panorámica describe y analiza las tecnologías existentes y emergentes para TDM de litio y sus parámetros de cuantificación (precisión, exactitud, límite de detección). Metodología: La búsqueda se realizó en Pubmed, Scopus, Web of Science y Google Scholar. Se incluyeron estudios según metodologías para la cuantificación de litio y las guías PRISMA-ScR. Los artículos se recolectaron usando https://www.rayyan.ai. Se seleccionaron de forma independiente, por medio de dos investigadores, resolviendo discrepancias con un tercer revisor. Los resultados fueron tabulados en Microsoft Excel. Se definió buena precisión si: Desviación Estándar Relativa <3%; aceptable, 3-5%; bajo, >5%. La exactitud se consideró buena si el error <5%; aceptable, 5-10%; baja, >10%. Resultados: De 2008 artículos encontrados, 22 cumplieron criterios de inclusión. De estos, 14 se referían a dispositivos de laboratorio, en los que la precisión fue baja en un tercio de los casos, y la mitad tuvo una buena precisión. La exactitud de un tercio fue buena, otro tercio fue baja, y el tercio restante no informó precisión. Los otros 8 estudios, de dispositivos portátiles, la precisión fue baja >60% de los casos y buena en el 25%. La exactitud fue baja en 50% de los casos y buena en alrededor de un tercio. Todos presentaron Límites de Detección que incluían el rango terapéutico del litio. Conclusiones: Entre las tecnologías para TDM de litio, la precisión y exactitud es un desafío, más en dispositivos portátiles, que no están disponibles. Palabras clave: Lithium, lithium monitoring, therapeutic drug monitoring, point- of-care systems.spa
dc.description.abstractenglishLithium has a narrow therapeutic margin. Therapeutic Drug Monitoring (TDM) of lithium concentrations has several barriers. Objectives: This scoping review aims to describe and analyze existing and emerging technologies for lithium TDM, including quantification parameters (precision, accuracy, limit of detection (LOD)). Methodology: The search was carried out in Pubmed, Scopus, Web of Science and Google Scholar. Studies were included according to the methodologies for the quantification of lithium and PRISMA- ScR guidelines. Articles were collected using https://www.rayyan.ai. Selection was carried out independently, by means of two researchers, solving discrepancies through a third reviewer. Results were tabulated in Microsoft Excel. Good precision was defined if its Relative Standard Deviation <3%; acceptable, from 3 to 5%; and low, >5%. Accuracy was considered good if error <5%; acceptable, 5-10%; and low if >10%. Results: Of the 2008 articles found, 22 met the inclusion criteria. Of these, 14 studies concerned laboratory devices, in which precision was low in one third of cases, and half had good precision. Accuracy of one third was good, another third was low, and the remaining third did not report accuracy. The other 8 studies were on portable devices, in these, precision was low in > 60% of the cases, and good in 25% of the studies. Accuracy was low in 50% of the cases, and good in a third. All presented LOD that included the therapeutic range of lithium. Conclusions: Among lithium TDM technologies, precision and accuracy remain a challenge, especially in portable devices that are not widely available.spa
dc.description.degreelevelEspecializaciónspa
dc.description.degreenameEspecialista en Psiquiatríaspa
dc.description.sponsorshipUniversidad El Bosquespa
dc.description.sponsorshipUniversidad de La Sabanaspa
dc.description.sponsorshipDeakin Universityspa
dc.format.mimetypeapplication/pdf
dc.identifier.instnameinstname:Universidad El Bosquespa
dc.identifier.reponamereponame:Repositorio Institucional Universidad El Bosquespa
dc.identifier.repourlrepourl:https://repositorio.unbosque.edu.co
dc.identifier.urihttps://hdl.handle.net/20.500.12495/11651
dc.language.isospaspa
dc.publisher.facultyFacultad de Medicinaspa
dc.publisher.grantorUniversidad El Bosquespa
dc.publisher.programEspecialización en Psiquiatríaspa
dc.rights.accessrightsinfo:eu-repo/semantics/closedAccess
dc.rights.accessrightshttps://purl.org/coar/access_right/c_14cb
dc.rights.localAcceso cerradospa
dc.subjectLitiospa
dc.subjectMonitoreo de litiospa
dc.subjectMonitoreo terapéutico de medicamentosspa
dc.subject.keywordsLithiumspa
dc.subject.keywordsLithium monitoringspa
dc.subject.keywordsTherapeutic drug monitoringspa
dc.subject.keywordsPoint of care systemsspa
dc.subject.nlmWM 100
dc.titleTecnologías existentes y emergentes para el monitoreo terapéutico del litio: una revisión panorámicaspa
dc.title.translatedExisting and Emerging Technologies for Therapeutic Monitoring of Lithium: A Scoping Review.spa
dc.type.coarhttps://purl.org/coar/resource_type/c_7a1f
dc.type.coarversionhttps://purl.org/coar/version/c_ab4af688f83e57aa
dc.type.driverinfo:eu-repo/semantics/bachelorThesis
dc.type.hasversioninfo:eu-repo/semantics/acceptedVersion
dc.type.localTesis/Trabajo de grado - Monografía - Especializaciónspa

Archivos

Bloque original
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
Trabajo de grado.pdf
Tamaño:
440.57 KB
Formato:
Adobe Portable Document Format
Descripción:
Tecnologías existentes y emergentes para el monitoreo terapéutico del litio: una revisión panorámica
Bloque de licencias
Mostrando 1 - 3 de 3
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.95 KB
Formato:
Item-specific license agreed upon to submission
Descripción:
No hay miniatura disponible
Nombre:
Carta de autorización.pdf
Tamaño:
844.52 KB
Formato:
Adobe Portable Document Format
Descripción:
Carta de autorización
No hay miniatura disponible
Nombre:
SANTIAGO PEDRAZA SANABRIA (1).pdf
Tamaño:
147.35 KB
Formato:
Adobe Portable Document Format
Descripción: