Evaluación de la tolerancia de los abutments de conexión hexagonal interna pasiva fabricados en aleaciones de cromo - cobalto

dc.contributor.advisorNeira Aragón, Martin Darío
dc.contributor.advisorTamayo Muñoz, Martha Cecilia
dc.contributor.advisorDíaz Báez, David Augusto
dc.contributor.authorMurillo Rivas, Enid María
dc.contributor.authorPinzón Rodríguez, María Fernanda
dc.contributor.authorUrbano Molano, Yineth Viviana
dc.date.accessioned2023-04-24T21:31:59Z
dc.date.available2023-04-24T21:31:59Z
dc.date.issued2019
dc.description.abstractLos abutments personalizados CAD-CAM en aleaciones en Cromo-Cobalto [Cro-Co]- que ya son comercialmente accesibles y de bajo costo, han demostrado tener buenas propiedades mecánicas que los hacen clínicamente aceptables; sin embargo, cuando su diseño es monolítico, las dimensiones del hexágono interno del abutment podrían verse afectadas al someterse a los procesos de colocación de la porcelana y esto puede generar problemas de adaptación y de micromovimiento en la interface abutment –implante. Por tal razón en este estudio se comparó la tolerancia de los abutments de conexión hexagonal interna pasiva prefabricados [Ti] con los personalizados-sinterizados en aleación Cro-Co y a estos últimos se les evaluaron los cambios dimensionales cuando son sometidos a los procesos de colocación de la porcelana. Para este estudio se utilizó una muestra no probabilística de 10 abutments prefabricados en Ti, y 10 abutments personalizados CAD-CAM en aleaciones de Cr-Co. A sus hexágonos se les evaluaron 7 mediciones longitudinales - y a los Cro- Co -estas mediciones también les fueron evaluadas en tres fases, la primera nuevos, la segunda posterior al proceso de colocación y cocción de la porcelana, y la tercera, posterior al proceso de pulido. Los análisis se realizaron sobre microfotografías obtenidas con un SEM a través del software Image Jfiji. Los resultados fueron reportados en micras (μ) y analizados estadísticamente mediante las pruebas de Friedman, ANOVA de medidas repetidas, t test y U Mann-Whitney; además se realizó un análisis descriptivo con respecto al parámetro de tolerancia máxima establecido [ISO 286-1:2010]. En los resultados se observa que hubo diferencias estadísticamente significativas al comparar los abutments personalizados y prefabricados nuevos en las variables: altura y perímetro del hexágono del abutment, ancho de extensión hexagonal, longitud del lado mayor del hexágono y diámetro máximo hexagonal. Para los abutments personalizados evaluados durante las tres fases se encontraron diferencias estadísticamente significativas solamente en las variables altura del hexágono del abutment y longitud del lado menor del hexágono y los datos descriptivos indican que la fase de pulido es la que genera los mayores cambios dimensionales. Estos resultados sugieren que las variaciones dimensionales que presentan los abutments personalizados CAD-CAM en Cro-Co - nuevos y cuando son sometidos a los procesos de colocación de la porcelana podrían llegar a afectar su adecuada adaptación y asentamiento, aumentando el riesgo de micromovimientos y las complicaciones mecánicas derivadas de la perdida de precarga tales como: aflojamiento, deformación y fractura del tornillo, deformación de las conexiones en el implante-abutment, e incluso fractura del implante.spa
dc.description.abstractenglishCAD-CAM personalised abutments made from chrome-cobalt alloy (Cro-Co) which are commercially accessible have been proven to have good mechanical properties and are clinically acceptable. However, when its design is monolithic, hexagon dimensions could be affected by the porcelain placement process and could generate adaption and micro-movement problems along the implant interface. The present study compared the tolerance of the mentioned prefabricated abutments (Ti) with CAD- CAM personalised Cro-Co alloy and the latter were evaluated for dimensional changes when subjected to the porcelain placement process. A non-probabilistic sample of ten prefabricated and personalised systems was used. The hexagons had seven longitudinal evaluations and the alloys had the same plus two additional phases: after the placement and after the sanding of the porcelain. The analysis was done on microphotographs obtained with a SEM with Image Jfiji software, results were reported in micron (μ) and statistically analysed with Friedman, repeated measures ANOVA, t test and U Mann-Whitney tests. An additional descriptive analysis of the maximum tolerance parameter was carried out also [ISO 286-1:2010]. Results showed statistically significant differences in: height, hexagonal perimeter, width of hexagonal extension, length of longest side and maximum hexagonal diameter. CAD-CAM personalised abutments evaluated during the three phases presented statistically significant differences regarding the height of the hexagon and length of shortest side only; descriptive data indicate that the sanding phase generates the greatest dimensional changes. Results suggest that the dimensional variations of the new Cro-Co abutments when subjected to the porcelain placement may affect its adequate adaptation and settlement.eng
dc.description.degreelevelEspecializaciónspa
dc.description.degreenameEspecialista en prostodonciaspa
dc.format.mimetypeapplication/pdf
dc.identifier.instnameinstname:Universidad El Bosquespa
dc.identifier.reponamereponame:Repositorio Institucional Universidad El Bosquespa
dc.identifier.repourlrepourl:https://repositorio.unbosque.edu.co
dc.identifier.urihttps://hdl.handle.net/20.500.12495/10316
dc.language.isospa
dc.publisher.facultyFacultad de Odontologíaspa
dc.publisher.grantorUniversidad El Bosquespa
dc.publisher.programEspecialización en prostodonciaspa
dc.rightsAtribución-NoComercial-CompartirIgual 4.0 Internacional*
dc.rights.accessrightshttps://purl.org/coar/access_right/c_abf2
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.localAcceso abiertospa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectAbutment dentalspa
dc.subjectConexión hexagonal internaspa
dc.subjectAbutment personalizado CAD CAMspa
dc.subjectDimensionamiento geométricospa
dc.subjectToleranciaspa
dc.subjectCromo-cobaltospa
dc.subject.keywordsDental abutmentspa
dc.subject.keywordsInternal hexagonal connectionspa
dc.subject.keywordsCAD-CAM personalised abutmentspa
dc.subject.keywordsGeometric dimensioningspa
dc.subject.keywordsTolerancespa
dc.subject.keywordsChrome-cobaltspa
dc.subject.nlmWU 500
dc.titleEvaluación de la tolerancia de los abutments de conexión hexagonal interna pasiva fabricados en aleaciones de cromo - cobaltospa
dc.title.translatedEvaluation of abutment tolerance with internal passive hexagonal connection made from chrome - cobalt alloyspa
dc.type.coarhttps://purl.org/coar/resource_type/c_7a1f
dc.type.coarversionhttps://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.driverinfo:eu-repo/semantics/bachelorThesis
dc.type.hasversioninfo:eu-repo/semantics/acceptedVersion
dc.type.localTesis/Trabajo de grado - Monografía - Especializaciónspa

Archivos

Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Evaluación de la tolerancia de los abutments de conexión hexagonal interna pasiva fabricados en aleaciones de cromo-cobalto
Tamaño:
2.04 MB
Formato:
Adobe Portable Document Format
Descripción:
Evaluación de la tolerancia de los abutments de conexión hexagonal interna pasiva fabricados en aleaciones de cromo-cobalto
Bloque de licencias
Mostrando 1 - 3 de 3
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:
No hay miniatura disponible
Nombre:
Acta.pdf
Tamaño:
537.78 KB
Formato:
Adobe Portable Document Format
Descripción:
Acta
No hay miniatura disponible
Nombre:
Carta.pdf
Tamaño:
539.7 KB
Formato:
Adobe Portable Document Format
Descripción:
Carta autorización