Comportamiento del ventrículo derecho de corazones trasplantados a una altura de 2640 msnm
dc.contributor.advisor | Rodriguez González, Maria Juliana | |
dc.contributor.author | Medina, Ramon | |
dc.contributor.author | Giraldo Peniche, Luis Enrique | |
dc.contributor.author | Jaimes Castellanos, Claudia | |
dc.contributor.author | López Pareja, Monica | |
dc.contributor.author | Ramirez, John | |
dc.contributor.author | Rodriguez Gonzalez, Maria Juliana | |
dc.contributor.author | Vasquez Rodriguez, Juan Felipe | |
dc.date.accessioned | 2021-03-12T20:40:40Z | |
dc.date.available | 2021-03-12T20:40:40Z | |
dc.date.issued | 2020 | |
dc.description.abstract | Antecedentes: los cambios fisiológicos de la altura en sistemas cardiovasculares generan aumento de la presión pulmonar. El efecto que estos cambios tienen en el ventrículo derecho de corazones trasplantados en alturas >2500msnm no está descrito. Objetivo: describir el comportamiento del ventrículo derecho por ecocardiograma en el post operatorio inmediato y a los meses 3-6-12 y 24 posterior del trasplante cardiaco en pacientes intervenidos a 2640msnm. Métodos: cohorte histórica de pacientes trasplantados de corazón un centro hospitalario de Bogotá D.C entre los años 2005 y 2019. Datos sociodemográficos, clínicos y de evaluación ecocardiográfica del ventrículo derecho en 5 momentos del seguimiento fueron analizados. Resultados: 91 pacientes fueron sometidos a trasplante cardiaco, 64% residentes a más de 2500 msnm en el post-operatorio. El 95% de los pacientes presentó disfunción ventricular derecha que fue predominantemente moderada (43%) con mejoría a partir del 3 mes post-operatorio. El TAPSE del post-operatorio inmediato fue de 8,9±4,9mm con recuperación desde el 3 mes (15,1±3,6 mm), que se mantuvo hasta el mes 24 (15,8±4,9mm). La PsAP del post-operatorio inmediato fue 39,2±8,2mmHg con descenso a partir del 3 mes hasta el mes 24 (31,0±5,0mmHg). No hubo diferencia entre los pacientes trasplantados residentes a más de 2500msnm y los residentes a menos de 2500msnm. La sobrevida a 5 años fue de 78%IC95%(60-85). Conclusión: Tras la realización de un trasplante cardiaco la mayoría de pacientes presentan disfunción ventricular derecha que mejora en los primeros 3 meses del postoperatorio. No hay diferencia entre los pacientes residentes postrasplante a más de 2500msnm y los residentes a menos de 2500msnm. | spa |
dc.description.abstractenglish | Background: High altitude cardiovascular adaptations generate pulmonary pressure increase. The effect of these increase on right ventricle of transplanted hearts at heights >2500masl is not described. Objective: describe echocardiography right ventricle behavior in the immediate post-operative period and at months 3-6-12 and 24 after heart transplantation in patients at 2640masl. Methods: historical cohort of heart transplant patients at hospital in Bogotá D.C between 2005 and 2019. Sociodemographic, clinical, and echocardiographic evaluation data of right ventricle at 5 follow-up moments were analyzed. Results: 91 patients underwent heart transplantation, 64% residents at more than 2,500masl in postoperative period. 95% of patients presented right ventricular dysfunction which was predominantly moderate (43%) with improvement after 3 months postoperatively. Immediate post-operative TAPSE was 8.9 ± 4.9mm with recovery from month 3 (15.1 ± 3.6mm), and remained until month 24 (15.8 ± 4.9mm). Immediate postoperative PsAP was 39.2±8.2mmHg, and decreased at month 24 (31.0±5.0mmHg). There was no difference between transplant patients residing at more than 2500masl and residents at less than 2500masl. The 5-year survival was 78% CI95% (60-85). Conclusion: After heart transplant, most patients present right ventricular dysfunction that improves in first 3 months. There is no difference between post-transplant resident patients at more than 2500masl and residents below 2500masl. | eng |
dc.description.degreelevel | Especialización | spa |
dc.description.degreename | Especialista en Cardiología de Adultos | spa |
dc.description.sponsorship | Fundación Cardioinfantil - Instituto de Cardiología | spa |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | instname:Universidad El Bosque | spa |
dc.identifier.reponame | reponame:Repositorio Institucional Universidad El Bosque | spa |
dc.identifier.repourl | repourl:https://repositorio.unbosque.edu.co | |
dc.identifier.uri | https://hdl.handle.net/20.500.12495/5640 | |
dc.language.iso | spa | |
dc.publisher.faculty | Facultad de Medicina | spa |
dc.publisher.grantor | Universidad El Bosque | spa |
dc.publisher.program | Especialización en cardiología adultos | spa |
dc.rights | Attribution-NonCommercial-ShareAlike 4.0 International | * |
dc.rights.accessrights | https://purl.org/coar/access_right/c_abf2 | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | 2020-08-18 | |
dc.rights.local | Acceso abierto | spa |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | * |
dc.subject | Trasplante cardiaco | spa |
dc.subject | Disfunción ventricular derecha | spa |
dc.subject | Hipertensión pulmonar | spa |
dc.subject | Altitud | spa |
dc.subject.decs | Trasplante de corazón | spa |
dc.subject.decs | Presión | spa |
dc.subject.decs | Ventrículos cardíacos | spa |
dc.subject.keywords | Heart transplant | spa |
dc.subject.keywords | Right ventricular dysfunction | spa |
dc.subject.keywords | Pulmonary hypertension | spa |
dc.subject.keywords | High altitude | spa |
dc.subject.nlm | WG 100 | |
dc.title | Comportamiento del ventrículo derecho de corazones trasplantados a una altura de 2640 msnm | spa |
dc.title.translated | Right ventricle performance in heart transplant at 2640 meters above sea level | spa |
dc.type.coar | https://purl.org/coar/resource_type/c_7a1f | |
dc.type.coarversion | https://purl.org/coar/version/c_ab4af688f83e57aa | |
dc.type.driver | info:eu-repo/semantics/bachelorThesis | |
dc.type.hasversion | info:eu-repo/semantics/acceptedVersion | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Especialización | spa |
Archivos
Bloque original
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- Comportamiento del ventrículo derecho de corazones trasplantados a una altura de 2640 msnm.docx
- Tamaño:
- 1.12 MB
- Formato:
- Microsoft Word XML
- Descripción:
- Documento Completo
Bloque de licencias
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: