Estudio comparativo en la resistencia a la fractura de cuatro diseños diferentes de preparación de carillas oclusales elaboradas en Disilicato de Litio

dc.contributor.advisorUlloa Beltrán, Viviana
dc.contributor.advisorFerraris, Federico
dc.contributor.advisorRivera, Jaime Rodrigo
dc.contributor.advisorDiaz Baez, David
dc.contributor.authorMartínez Zafra, Natalia
dc.date.accessioned2022-01-19T17:49:13Z
dc.date.available2022-01-19T17:49:13Z
dc.date.issued2021-07-30
dc.description.abstractLas carillas oclusales son preparaciones delgadas adhesivas, de cobertura parcial, las cuales están indicadas, principalmente, en condiciones de erosión avanzada de la superficie oclusal o en casos de restauraciones clínicas donde la dimensión vertical necesita ser aumentada. Por sus excelentes propiedades ópticas, características mecánicas, facilidad de procesamiento y posibilidad de unión adhesiva, asegurando un enfoque mínimamente invasivo, las cerámicas de vidrio de Disilicato de litio se han convertido rápidamente en uno de los materiales restauradores más populares en casi todas las indicaciones de prostodoncia como tratamiento alternativo para el reemplazo de estructura dental. Por tanto, el objetivo de este estudio fue comparar la resistencia a la fractura de las carillas oclusales elaboradas en Disilicato de litio realizando cuatro diseños diferentes de preparaciones. En este estudio experimental in vitro, se usó una muestra probabilística de ocho especímenes por cada uno de los cuatro grupos evaluados: junta a tope, bisel, hombro y sin preparación. Cada restauración fue diseñada de 1.0mm de espesor y para la fabricación se utilizó Disilicato de litio IPS e.max Press. Una vez cementadas en los molares humanos mediante estrictos protocolos de adhesión, fueron sometidas a prueba de resistencia a la fractura en la maquina universal de pruebas. Para analizar los datos se utilizó la prueba de normalidad Shapiro wilk para evaluar la distribución de cada grupo de datos. Dado que los datos se distribuyeron de manera normal, se utilizó ANOVA de una vía la cual mostró diferencias estadísticamente significativas de la resistencia a la fractura entre los grupos (p=0.0275); No obstante, el análisis de la prueba Post-Hoc de Sidak no mostró diferencias estadísticas entre las comparaciones múltiples; Sin embargo, el grupo 4 mostró una tendencia a presentar mayor resistencia a la fractura en comparación con el grupo 3 (p=0.051). Podemos concluir que los grupos con una preparación más conservadora, demostraron un mejor rendimiento biomecánico frente a cargas aplicadas. Serán necesarias más investigaciones, para definir cuál diseño de preparación presenta mejores ventajas biomecánicas a largo plazo.spa
dc.description.abstractenglishOcclusal veneers are thin, partial coverage adhesive preparations, which are primarily appropriate for advanced erosion on the occlusal surface or in cases of clinical restorations in which the vertical dimension of teeth must be increased. Due to their excellent optical properties, mechanical characteristics, ease of processing and possibility for adhesive bonding, which ensure a minimally invasive approach, lithium disilicate glass ceramics have quickly become one of the most popular restorative materials in almost all prosthodontic indications as an alternative treatment to replacing dental structure. Therefore, the objective of this study was to compare the fracture toughness of occlusal veneers made of lithium disilicate with four different preparation designs. A probabilistic sample of eight specimens for each one of the four assessed groups was used in this in vitro experimental study: butt-joint, chamfer, shoulder and without preparation. Each restoration was designed with 1.0 mm of thickness, and IPS e.max Press Lithium Disilicate was used to manufacture them. Once cemented in human molars following strict adhesion protocols, they were submitted to fracture toughness tests on the universal test machine. The Shapiro-Wilk Normality Test was used to analyze the distribution of each group of data. Since the data was normally distributed, a one-way ANOVA was applied, which showed statistically significant differences in fracture toughness between the groups (p=0.0275). However, the Sidak Post-Hoc test analysis did not show statistical differences between the multiple comparisons. Nevertheless, group 4 showed a tendency to have a greater fracture toughness compared to group 3 (p=0.051). We can conclude that the groups with a more conservative preparation demonstrated greater biomechanical performance against the applied forces. More research will be necessary to define the preparation design with the best longterm biomechanical advantages.eng
dc.description.degreelevelEspecializaciónspa
dc.description.degreenameEspecialista en Operatoria Dental Estética y Materiales Dentalesspa
dc.description.sponsorshipUniCIEO, ACD Laboratorio Dental, Ivoclar Vivadentspa
dc.format.mimetypeapplication/pdf
dc.identifier.instnameinstname:Universidad El Bosquespa
dc.identifier.reponamereponame:Repositorio Institucional Universidad El Bosquespa
dc.identifier.repourlrepourl:https://repositorio.unbosque.edu.co
dc.identifier.urihttps://hdl.handle.net/20.500.12495/6506
dc.language.isospa
dc.publisher.facultyFacultad de Odontologíaspa
dc.publisher.grantorUniversidad El Bosquespa
dc.publisher.programEspecialización en Operatoria Dental Estética y Materiales Dentalesspa
dc.rightsAtribución-CompartirIgual 4.0 Internacional*
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightshttps://purl.org/coar/access_right/c_abf2
dc.rights.localAcceso abiertospa
dc.rights.urihttps://creativecommons.org/licenses/by-sa/4.0/*
dc.subjectResistencia a la fracturaspa
dc.subjectCerámica de vidriospa
dc.subjectCarillas dentalesspa
dc.subjectDisilicato de litiospa
dc.subjectPreparación dentalspa
dc.subject.decsCoronas con frente estéticospa
dc.subject.decsEpidemiología experimentalspa
dc.subject.decsMateriales dentalesspa
dc.subject.keywordsFracture toughnessspa
dc.subject.keywordsGlass ceramicsspa
dc.subject.keywordsDental veneersspa
dc.subject.keywordsLithia disilicatespa
dc.subject.keywordsTooth preparationspa
dc.subject.nlmWU300
dc.titleEstudio comparativo en la resistencia a la fractura de cuatro diseños diferentes de preparación de carillas oclusales elaboradas en Disilicato de Litiospa
dc.title.translatedEffect of preparation design on fracture resistance of Lithium Disilicate occlusal veneersspa
dc.type.coarhttps://purl.org/coar/resource_type/c_7a1f
dc.type.coarversionhttps://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.driverinfo:eu-repo/semantics/bachelorThesis
dc.type.hasversioninfo:eu-repo/semantics/acceptedVersion
dc.type.localTesis/Trabajo de grado - Monografía - Pregradospa

Archivos

Bloque original
Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
Martinez_Zafra_Natalia_2021.pdf
Tamaño:
1.53 MB
Formato:
Adobe Portable Document Format
Descripción:
No hay miniatura disponible
Nombre:
Martinez_Zafra_Natalia_2021_Formato_de_entrega.pdf
Tamaño:
350.2 KB
Formato:
Adobe Portable Document Format
Descripción:
No hay miniatura disponible
Nombre:
Martinez_Zafra_Natalia_2021_Probatus.pdf
Tamaño:
332.71 KB
Formato:
Adobe Portable Document Format
Descripción:
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: