Valoración del ángulo de la cámara anterior mediante biomicroscopia ultrasónica, gonioscopia y examen de Van Herick

dc.contributor.authorCarrizosa Murcia, Marcelo
dc.contributor.authorRey Rodríguez, Diana Valeria
dc.contributor.orcidRey Rodríguez, Diana Valeria [0000-0003-1106-6235]
dc.contributor.orcidCarrizosa Murcia, Marcelo [0000-0003-0712-0024]
dc.date.accessioned2020-05-11T21:14:03Z
dc.date.available2020-05-11T21:14:03Z
dc.date.issued2019
dc.description.abstractenglishObjective: To compare the measurement of the angle of the anterior chamber using ultrasound biomicroscopy (UBM), gonioscopy and the Van Herick examination. Methods: An observational comparative study was carried out between 3 different methods for the estimation of the iridocorneal angle. A total of 30 subjects with open and closed angles were evaluated using UBM, gonioscopy and Van Herick. In the UBM and gonioscopy assessment all the quadrants were included in the analysis, and in the Van Herick examination the nasal and temporal quadrant were also analyzed. All the examinations included the assessment of both eyes under photo-optical and scotopic illumination conditions. These findings were compared with the kappa concordance test. Results: There was no statistically significant difference between the 3 methods in the evaluation of the state of the iridocorneal angle. The consistency between UBM and gonioscopy was better (kappa 0.93) in relation to the estimation of the angle with Van Herick (kappa 0.83). Conclusions: The UBM, gonioscopy and Van Herick examinations have comparable results, although gonioscopy in the first instance would be indicated as a routine test for identification of angular closure.eng
dc.format.mimetypeapplication/pdf
dc.identifier.doihttps://doi.org/10.1016/j.oftal.2018.09.011
dc.identifier.issn1989-7286
dc.identifier.urihttps://hdl.handle.net/20.500.12495/2582
dc.language.isoeng
dc.publisherElsevierspa
dc.publisher.journalArchivos de la sociedad española de oftalmologiaspa
dc.relation.ispartofseriesArchivos de la sociedad española de oftalmologia, 1989-7286, Vol. 94, Nro. 3, 2019, 114-118spa
dc.relation.urihttps://www.sciencedirect.com/science/article/abs/pii/S0365669118303083
dc.rights.creativecommons2018
dc.rights.localAcceso cerradospa
dc.subjectBiomiscroscopia de ultrasonidospa
dc.subjectGonioscopiaspa
dc.subjectConcordanciaspa
dc.subject.decsMicroscopía acústicaspa
dc.subject.decsDiagnóstico por imagenspa
dc.subject.decsGonioscopíaspa
dc.subject.keywordsUltrasonic biomicroscopy (UBM)spa
dc.subject.keywordsGonioscopyspa
dc.subject.keywordsConcordancespa
dc.titleValoración del ángulo de la cámara anterior mediante biomicroscopia ultrasónica, gonioscopia y examen de Van Herickspa
dc.title.translatedEvaluation of the angle of the anterior chamber using ultrasound biomicroscopy, gonioscopy and a Van Herick examinationspa
dc.typearticlespa
dc.type.hasversioninfo:eu-repo/semantics/publishedVersion
dc.type.localartículospa

Archivos

Bloque original
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
Carrizosa Murcia, Marcelo. Rey Rodríguez, Diana V._2019.pdf
Tamaño:
548.58 KB
Formato:
Adobe Portable Document Format
Descripción:
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones