Evaluación de la concordancia - en términos de precisión y exactitud - del software InLab versión 18.1 [dentsply sirona] como instrumento para la medición de los cambios dimensionales de los materiales de impresión. Protocolo

dc.contributor.advisorTamayo Muñoz, Martha Cecilia
dc.contributor.advisorDíaz Báez, David Augusto
dc.contributor.authorAcero Amaya, Norma Tatiana
dc.contributor.authorPercy Percy, Samira María
dc.contributor.authorSánchez Perilla, Claudia Juliana
dc.date.accessioned2023-03-03T13:47:59Z
dc.date.available2023-03-03T13:47:59Z
dc.date.issued2020
dc.description.abstractAntecedentes: La estabilidad dimensional es una propiedad física que se evalúa a los materiales de impresión dental y se ha realizado con diferentes instrumentos - todos sobre modelos de yeso- y de ellos el que es considerado como método estándar es el calibrador digital. Actualmente en odontología digital se cuenta con el software InLab SW 18.1 - Dentsply Sirona que cuenta con la herramienta distancia que permite mediciones lineales muy precisas. Este junto con el escáner extraoral InEos X5 podrían servir de manera eficiente como instrumento para evaluar estabilidad dimensiona de materiales de impresión, pero no han sido validados para tal fin. Objetivo: Determinar la concordancia del Software InLab SW 18.1 como instrumento para la medición de cambios dimensionales de los materiales de impresión dental. Materiales y métodos: En este estudio de evaluación de pruebas diagnósticas con análisis de concordancia se evaluará la herramienta distancia del Software InLab SW 18.1 [HD] Se utilizará como prueba estándar de oro[ME] un Calibrador digital LCD - calibrado y certificado [Norma ADA19/2004]. Para evaluar la exactitud se utilizará una muestra probabilística de 50 modelos edéntulos del maxilar superior -de yeso y digitales- tomados de 50 pacientes y para precisión una muestra probabilística de 35 modelos edéntulos. Sobre los modelos -de yeso y digitales- se identificarán los 4 puntos de referencia denominados de manera diferente para las mediciones oclusales [ABCD] y para las vestibulares [EFGH]: Puntos A/E y B/F: eminencias caninas derecha e izquierda respectivamente y puntos C/G y D/H: tuberosidad maxilar derecha e izquierda. Con base en estos puntos se realizarán 4 mediciones lineales: 2 oclusales [AB y CD] y 2 Vestibulares [EG y FH]. Todas las medidas se reportarán en mm y serán realizadas por un examinador calibrado para los dos métodos [ICC >0.9]. La exactitud se evaluará comparando los resultados obtenidos por el ME sobre los modelos de yeso con los obtenidos por HD sobre los modelos digitales y para evaluar la precisión se compararán los resultados obtenidos entre tres mediciones realizadas por la HD sobre los modelos digitales. Para el análisis estadístico se utilizará la prueba de CCI con sus intervalos de confianza, todos los análisis se realizarán con un nivel de confianza del 95%. Este proyecto fue aprobado por el Comité de ética Ad Hoc de la Universidad El Bosque [Acta número 002-2020]. Este proyecto se ejecutará una vez haya viabilidad de atender pacientes en la Universidad.spa
dc.description.abstractenglishBackground: Dimensional stability is a physical property by which dental impression materials are evaluated and is done with different instruments – all on cast models – and the digital calibrator is considered the standard method. InLab SW 18.1 - Dentsply Sirona incorporates a distance tool allowing very precise linear measurements, which along with the InEos X5 extra-oral scanner could be efficient tools for said evaluation; however, they have not been validated for such task. Objective: to determine the accord of InLab SW 18.1 as an instrument to measure dimensional changes of dental impression materials. Materials and methods: This is a diagnostic trial evaluation with accord analysis in order to evaluate the tool distance of the mentioned software (HD), the gold standard (ME) is an LCD digital calibrator, calibrated and certified [Norm ADA19/2004]. A probabilistic sample of 50 edentulous maxillary models (cast and digital) taken from 50 patients was used for trueness and a probabilistic sample of 35 edentulous models for precision. Four reference points were identified on the cast and digital models, individually denominated for occlusal measurements (ABCD) and for vestibular (EFGH): points A/E and B/F: canine eminences right and left respectively and points C/G and D/H: maxillary tuberosity right and left. Four linear measurements will be done based on these points: two occlusal (AB and CD) and two vestibular (EG and FH). All measurements will be reported in mm and carried out by a calibrated examiner for both methods [ICC >0.9]. Trueness will be evaluated comparing the results obtained by ME on the cast models obtained by HD on the digital models and results between three measurements by HD on digital models will be used for precision. The CCI test will be used for statistical analysis with its confidence intervals, all analyses will be accomplished with a 95% confidence level. The ad hoc ethics committee of El Bosque University (act number 002-2020) approved this project and will be performed once there is viability for patient attention at the university.eng
dc.description.degreelevelEspecializaciónspa
dc.description.degreenameEspecialista en prostodonciaspa
dc.format.mimetypeapplication/pdf
dc.identifier.instnameinstname:Universidad El Bosquespa
dc.identifier.reponamereponame:Repositorio Institucional Universidad El Bosquespa
dc.identifier.repourlrepourl:https://repositorio.unbosque.edu.co
dc.identifier.urihttps://hdl.handle.net/20.500.12495/10096
dc.language.isospa
dc.publisher.facultyFacultad de Odontologíaspa
dc.publisher.grantorUniversidad El Bosquespa
dc.publisher.programEspecialización en prostodonciaspa
dc.rightsAtribución-NoComercial-CompartirIgual 4.0 Internacional*
dc.rights.accessrightshttps://purl.org/coar/access_right/c_abf2
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.localAcceso abiertospa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectEstabilidad dimensionalspa
dc.subjectMateriales de impresión dentalspa
dc.subjectConcordanciaspa
dc.subjectInLab CADspa
dc.subjectCalibrador digitalspa
dc.subject.keywordsDimensional stabilityspa
dc.subject.keywordsDental impression materialsspa
dc.subject.keywordsAccordspa
dc.subject.keywordsInLab CADspa
dc.subject.keywordsDigital calibratorspa
dc.subject.nlmWU 500
dc.titleEvaluación de la concordancia - en términos de precisión y exactitud - del software InLab versión 18.1 [dentsply sirona] como instrumento para la medición de los cambios dimensionales de los materiales de impresión. Protocolospa
dc.title.translatedAccuracy evaluation - in terms of precision and trueness – of InLab v18.1 [dentsply/sirona] as an instrument for dimensional change measurement of impression materials. Protocolspa
dc.type.coarhttps://purl.org/coar/resource_type/c_7a1f
dc.type.coarversionhttps://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.driverinfo:eu-repo/semantics/bachelorThesis
dc.type.hasversioninfo:eu-repo/semantics/acceptedVersion
dc.type.localTesis/Trabajo de grado - Monografía - Especializaciónspa

Archivos

Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
Evaluación de la concordancia - en términos de precisión y exactitud - del software InLab versión 18.1 [dentsply sirona] como instrumento para la medición de los cambios dimensionales de los materiales de impresión. Protocolo
Tamaño:
1.72 MB
Formato:
Adobe Portable Document Format
Descripción:
Evaluación de la concordancia - en términos de precisión y exactitud - del software InLab versión 18.1 [dentsply sirona] como instrumento para la medición de los cambios dimensionales de los materiales de impresión. Protocolo
Bloque de licencias
Mostrando 1 - 3 de 3
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:
No hay miniatura disponible
Nombre:
Carta de autorización
Tamaño:
817.54 KB
Formato:
Adobe Portable Document Format
Descripción:
Carta autorización
No hay miniatura disponible
Nombre:
Probatus
Tamaño:
534.75 KB
Formato:
Adobe Portable Document Format
Descripción:
Probatus