Manejo de quemaduras oculares con implante de membrana amniótica: Revisión sistemática de la literatura

dc.contributor.advisorGarcia Lozada, Diana Georgina
dc.contributor.advisorMurcia Carrizosa, Marcelo
dc.contributor.authorDuarte Morales, Alison Yineth
dc.contributor.authorFlorez Ricardo, Angie Paola
dc.contributor.authorGarzón Menjura, Angie Valentina
dc.date.accessioned2022-02-12T01:58:09Z
dc.date.available2022-02-12T01:58:09Z
dc.date.issued2022-01
dc.description.abstractObjetivo: Establecer la efectividad y seguridad de la membrana amniótica en la reparación de la superficie ocular tras quemaduras químicas en comparación al tratamiento médico convencional. Metodología: Estudio integrativo, observacional y retrospectivo, de revisión sistemática de la literatura, en el cual se realizaron búsquedas electrónicas en OVID (MEDLINE Y CENTRAL- COCHRANE), EMBASE, LILASC, EPISTEMONIKOS, GOOGLE SCHOLAR. Incluyendo literatura gris como OPENGRAY y PROQUEST (TESIS Y TESINAS), limitando la búsqueda desde el año 2000 al 2021. La extracción de los datos se realizó mediante la herramienta web Rayyan en base a las variables de interés: tipo de estudio, titulo, autor, año, país, tamaño de la muestra, sexo, grado de quemadura, agente causal, técnica de implantación, tratamiento control, tratamiento experimental, complicaciones y resultados. La evaluación de riesgo de sesgos se implementó a través de la herramienta Rob2 de Cochrane. Resultados: Se incluyeron cuatro ensayos clínicos (Tamhane 2005, Tandon 2011, Namrata 2016, Eslani 2018) en los cuales no hubo una diferencia estadísticamente significativa en la reepitelización corneal, agudeza visual entre el tratamiento de membrana amniótica y la terapia médica convencional. Por otra parte, se observaron menores complicaciones de neovascularización y simbléfaron en la aplicación de membrana. Así mismo, se identificó con mayor frecuencia la técnica de implantación de recubrimiento en el tejido de membrana. Conclusiones: Carecen pruebas de calidad a favor del uso de la membrana amniótica en consecuencia a la falta de especificidad en el agente causal y las medidas de resultado no uniformes, que son algunos de los factores que complicaron la búsqueda de pruebas claras con respecto a este tratamiento.spa
dc.description.abstractenglishObjective: To establish the effectiveness and safety of the amniotic membrane in the repair of the ocular surface after chemical burns compared to conventional medical treatment. Methodology: Integrative, observational and retrospective study, systematic review of the literature, in which electronic searches were performed in OVID (MEDLINE AND CENTRAL-COCHRANE), EMBASE, LILASC, EPISTEMONIKOS, GOOGLE SCHOLAR. Including gray literature such as OPENGRAY and PROQUEST (THESIS AND THESIS), limiting the search from 2000 to 2021. Data extraction was performed using the Rayyan web tool based on the variables of interest: type of study, title, author, year, country, sample size, sex, degree of burn, causal agent, implantation technique, control treatment, experimental treatment, complications and results. The risk of bias assessment was implemented using Cochrane's Rob2 tool. Results: Four clinical trials were included (Tamhane 2005, Tandon 2011, Namrata 2016, Eslani 2018) in which there was no statistically significant difference in corneal re-epithelialization, visual acuity between amniotic membrane treatment and conventional medical therapy. On the other hand, fewer neovascularization and symblepharon complications were observed in the membrane application. Likewise, the coating implantation technique in the membrane tissue was identified more frequently. Conclusions: There is a lack of quality evidence in favor of the use of the amniotic membrane due to the lack of specificity in the causal agent and non-uniform outcome measures, which are some of the factors that complicated the search for clear evidence regarding this treatment.eng
dc.description.degreelevelPregradospa
dc.description.degreenameOptómetraspa
dc.format.mimetypeapplication/pdf
dc.identifier.instnameinstname:Universidad El Bosquespa
dc.identifier.reponamereponame:Repositorio Institucional Universidad El Bosquespa
dc.identifier.repourlrepourl:https://repositorio.unbosque.edu.co
dc.identifier.urihttps://hdl.handle.net/20.500.12495/6816
dc.language.isospa
dc.publisher.facultyFacultad de Medicinaspa
dc.publisher.grantorUniversidad El Bosquespa
dc.publisher.programOptometríaspa
dc.rightsAtribución-NoComercial-CompartirIgual 4.0 Internacional*
dc.rightsAtribución-NoComercial-CompartirIgual 4.0 Internacional*
dc.rightsAtribución-NoComercial-CompartirIgual 4.0 Internacional*
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightshttps://purl.org/coar/access_right/c_abf2
dc.rights.localAcceso abiertospa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectMembrana amnióticaspa
dc.subjectQuemadura ocularspa
dc.subjectÁlcalisspa
dc.subjectÁcidosspa
dc.subject.ddcWW704
dc.subject.keywordsAmnionspa
dc.subject.keywordsEye burnsspa
dc.subject.keywordsAlkaliesspa
dc.subject.keywordsAcidsspa
dc.titleManejo de quemaduras oculares con implante de membrana amniótica: Revisión sistemática de la literaturaspa
dc.title.translatedManagement of ocular burns with amniotic membrane implant: Systematic review of the literaturespa
dc.type.coarhttps://purl.org/coar/resource_type/c_7a1f
dc.type.coarversionhttps://purl.org/coar/version/c_ab4af688f83e57aa
dc.type.driverinfo:eu-repo/semantics/bachelorThesis
dc.type.hasversioninfo:eu-repo/semantics/acceptedVersion
dc.type.localTesis/Trabajo de grado - Monografía - Pregradospa

Archivos

Bloque original
Mostrando 1 - 2 de 2
Cargando...
Miniatura
Nombre:
Duarte_Morales_ Alison_ Yineth_2022.pdf
Tamaño:
624.54 KB
Formato:
Adobe Portable Document Format
Descripción:
Manejo de quemaduras oculares con implante de membrana amniótica: Revisión sistemática de la literatura 
No hay miniatura disponible
Nombre:
Duarte_Morales_Alison_Yineth_2022_Carta_de_autorización.pdf
Tamaño:
479.44 KB
Formato:
Adobe Portable Document Format
Descripción:
Carta de autorización
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones