Estimation of intracranial pressure by ultrasound of the optic nerve sheath in an animal model of intracranial hypertension

dc.contributor.authorJeng, Brasil Chian Ping
dc.contributor.authorde Andrade, Almir Ferreira
dc.contributor.authorBrasil, Sérgio
dc.contributor.authorBor Seng Shu, Edson
dc.contributor.authorBelon, Alessandro Rodrigo
dc.contributor.authorRobertis, Maira
dc.contributor.authorde Lima Oliveira, Marcelo
dc.contributor.authorRubiano, Andrés Mariano
dc.contributor.authorGodoy, Daniel Agustín
dc.contributor.authorTeixeira, Manoel Jacobsen
dc.contributor.authorPaiva, Wellingson Silva
dc.contributor.orcidRubiano, Andrés Mariano [0000-0001-8931-3254]
dc.date.accessioned2023-01-18T16:33:45Z
dc.date.available2023-01-18T16:33:45Z
dc.date.issued2021
dc.description.abstractAntecedentes: La ecografía del diámetro de la vaina del nervio óptico (ONSD) se ha utilizado como alternativa no invasiva y rentable a la monitorización invasiva de la presión intracraneal (PIC). Sin embargo, aún se desconoce el comportamiento temporal del ONSD en la hipertensión intracraneal (HIC) y su alivio mediante infusión salina o cirugía. El objetivo de este estudio fue correlacionar la presión intracraneal (PIC) y la ultrasonografía de la vaina del nervio óptico (ONS) en un modelo animal experimental de HIC y determinar el intervalo necesario para que la ONSD vuelva a los niveles basales. Métodos: Se realizó un estudio experimental en 30 cerdos. La ONSD se evaluó mediante ecografía a diferentes PIC generadas por inflado intracraneal con balón, infusión salina y desinflado con balón, y se midió utilizando un catéter intraventricular. Resultados: Todas las variables obtenidas por ultrasonografía ONS como ONSD izquierdo, derecho y promedio (AON) fueron estadísticamente significativas para estimar el valor de la PIC. La ONSD cambió inmediatamente después del inflado del balón y volvió a los valores basales tras un retraso medio de 30 min después del desinflado del balón (p = 0,016). No se observó significación estadística en los valores de PIC y ONSD con la infusión de solución salina hipertónica. En este modelo porcino, la PIC y la ONSD mostraron una correlación lineal y la PIC pudo estimarse mediante la fórmula: -80,5 + 238,2 × AON. Conclusiones: En el presente estudio, la ecografía para medir la ONSD mostró una correlación lineal con la PIC, aunque se observó un breve retraso en volver a los niveles basales en el caso de alivio súbito de la HIC.spa
dc.description.abstractenglishBackground: Ultrasound of the optic nerve sheath diameter (ONSD) has been used as a non-invasive and cost-effective bedside alternative to invasive intracranial pressure (ICP) monitoring. However, ONSD time-lapse behavior in intracranial hypertension (ICH) and its relief by means of either saline infusion or surgery are still unknown. The objective of this study was to correlate intracranial pressure (ICP) and ultrasonography of the optic nerve sheath (ONS) in an experimental animal model of ICH and determine the interval needed for ONSD to return to baseline levels. Methods: An experimental study was conducted on 30 pigs. ONSD was evaluated by ultrasound at different ICPs generated by intracranial balloon inflation, saline infusion, and balloon deflation, and measured using an intraventricular catheter. Results: All variables obtained by ONS ultrasonography such as left, right, and average ONSD (AON) were statistically significant to estimate the ICP value. ONSD changed immediately after balloon inflation and returned to baseline after an average delay of 30 min after balloon deflation (p = 0.016). No statistical significance was observed in the ICP and ONSD values with hypertonic saline infusion. In this swine model, ICP and ONSD showed linear correlation and ICP could be estimated using the formula: −80.5 + 238.2 × AON. Conclusion: In the present study, ultrasound to measure ONSD showed a linear correlation with ICP, although a short delay in returning to baseline levels was observed in the case of sudden ICH relief.eng
dc.format.mimetypeapplication/pdf
dc.identifier.doihttps://doi.org/10.1016/j.jocn.2021.01.021
dc.identifier.instnameinstname:Universidad El Bosquespa
dc.identifier.issn1532-2653
dc.identifier.reponamereponame:Repositorio Institucional Universidad El Bosquespa
dc.identifier.repourlrepourl:https://repositorio.unbosque.edu.co
dc.identifier.urihttps://hdl.handle.net/20.500.12495/9638
dc.language.isoeng
dc.publisherElsevier Ltd.spa
dc.publisher.journalJournal of Clinical Neurosciencespa
dc.relation.ispartofseriesJournal of Clinical Neuroscience, 1532-2653, Vol 86, 2021, Pag 174-179spa
dc.relation.urihttps://linkinghub.elsevier.com/retrieve/pii/S0967-5868(21)00030-8
dc.rights.accessrightshttps://purl.org/coar/access_right/c_14cb
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightsAcceso cerrado
dc.subjectModelo animalspa
dc.subjectLesión cerebralspa
dc.subjectHipertensión intracranealspa
dc.subjectDiámetro de la vaina del nervio ópticospa
dc.subjectEcografíaspa
dc.subject.keywordsAnimal modelspa
dc.subject.keywordsBrain injuryspa
dc.subject.keywordsIntracranial hypertensionspa
dc.subject.keywordsOptic nerve sheath diameterspa
dc.subject.keywordsUltrasonographyspa
dc.titleEstimation of intracranial pressure by ultrasound of the optic nerve sheath in an animal model of intracranial hypertensionspa
dc.title.translatedEstimation of intracranial pressure by ultrasound of the optic nerve sheath in an animal model of intracranial hypertensionspa
dc.type.coarhttps://purl.org/coar/resource_type/c_6501
dc.type.coarversionhttps://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.driverinfo:eu-repo/semantics/article
dc.type.hasversioninfo:eu-repo/semantics/publishedVersion
dc.type.localArtículo de revista

Archivos

Bloque original
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
Estimation of intracranial pressure by ultrasound of the optic nerve sheath in an animal model of intracranial hypertension.pdf
Tamaño:
547.19 KB
Formato:
Adobe Portable Document Format
Descripción:
Estimation of intracranial pressure by ultrasound of the optic nerve sheath in an animal model of intracranial hypertension
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones