Exactitud de las imágenes digitales obtenidas por dos métodos de impresión dental- escáner extraoral [Ineos x5®] e intraoral [Cerec primescam®] - en molares inferiores con preparación para corona completa con dientes adyacentes
dc.contributor.advisor | Tamayo Muñoz, Martha Cecilia | |
dc.contributor.advisor | Díaz Báez, David Augusto | |
dc.contributor.advisor | Sarmiento, Brayan | |
dc.contributor.advisor | Pérez Hernandez, José Leonardo | |
dc.contributor.author | Castro Romero, Verónica | |
dc.contributor.author | Díaz Real, María Alejandra | |
dc.contributor.author | Benavides Ramírez, Carlos Giovany | |
dc.date.accessioned | 2023-03-17T13:25:44Z | |
dc.date.available | 2023-03-17T13:25:44Z | |
dc.date.issued | 2023 | |
dc.description.abstract | Antecedentes: La odontología digital ofrece dos métodos para obtener una impresión dental; el escáner intraoral con el que las imágenes se obtienen directamente a partir de la boca del paciente y el extraoral en el que se obtienen de un modelo de yeso vaciado a partir de una impresión convencional. Para que las impresiones con estas técnicas tengan efectividad clínica, deben reproducir exactamente las preparaciones de los dientes que se van a restaurar, sin embargo, se ha observado que en molares inferiores existen factores que afectan esta exactitud tales como la presencia o ausencia de dientes adyacentes o la posición de la línea terminal con respecto al margen gingival los cuales no han sido evaluados con las últimas versiones de dichos escáneres. Objetivo: Evaluar la exactitud de las imágenes digitales obtenidas por dos métodos de impresión dental digital –intraoral y extraoral- de los ángulos formados en la línea terminal de las preparación para corona completa cerámica ubicadas de manera yuxta, sub y supra gingivalmente, con diente adyacente Métodos: En este estudio experimental in vitro con análisis de concordancia, se utilizó una muestra probabilística para evaluar la exactitud de 50 modelos Nissin® por cada una de las 3 líneas terminales evaluadas: yuxtagingival, subgingival y supragingival. Como estándar de oro se utilizaron las imágenes de 50 modelos con las 3 condiciones líneas establecidas escaneadas directamente con el escáner extraoral INEOS X5. Los modelos fueron escaneados con cada una de las técnicas de impresión evaluadas. Los archivos *stl obtenidos de los escaneos fueron importados al programa de diseño 3D Solid Edge versión 2020 para realizar la medición de los ángulos- interno y externo- de las líneas terminales de cada cara del diente, el evaluador fue calibrado [CCI > 0.9] Se realizó análisis estadístico de concordancia para muestras cuantitativas mediante las pruebas de CCI, CCC además se analizaron las diferencias de medias entre las medidas de las muestras de escáner intraoral y extraoral con el estándar de oro con la prueba t de student. Resultados y conclusiones: Se observó que, para molares inferiores con dientes adyacentes, los dos escáneres lograron una exactitud mayor o igual a sustancial (CCI > 0.61) en la línea supragingival para las caras mesial y lingual, y solo el escáner intraoral logro ese mismo nivel de exactitud para esta línea en la cara vestibular. La cara distal fue la que menor exactitud presento en todas las líneas terminales estudiadas con los dos escáneres evaluados (CCI < 0.60) (p >0.05). Bajos los límites de este estudio se puede concluir que el escáner intraoral fue quien obtuvo los mayores valores de exactitud en todas las condiciones evaluadas, sin embargo, solo logro una exactitud mayor sustancial en la línea supragingival. | spa |
dc.description.abstractenglish | Background: digital dentistry offers two methods for dental impressions: the intra-oral scanner, with which images are obtained directly from the patient’s mouth, and extra-oral, in which they are obtained from a poured cast. These must precisely reproduce the dental preparations to be restored in order to be clinically effective. However, factors have been observed on lower molars, such as presence or absence of adjacent teeth or the terminal edge with regards to the gingival margin, which affect said trueness. Objective: to evaluate trueness of digital images obtained by the mentioned methods of the angles formed on the prepared terminal edge for full ceramic crown in juxta, sub and supra gingival locations with adjacent tooth. Methods: an in vitro experimental study with concordance analysis and a probabilistic sample to evaluate trueness of 50 Nissin® models for each of the three mentioned gingival edges. The gold standard were the images of 50 models with the three edges, directly scanned with INEOS X5 extra-oral scanner with each of the impression techniques. The *stl files were loaded to 3D Solid Edge v.2020 in order to measure internal and external angles of the terminal edge for each tooth. The evaluator was calibrated [CCI > 0.9], a concordance statistical analysis for quantitative samples with CCI and CCC tests was done and median differences were analysed with Student’s t test. Results and conclusions: both scanners yielded a trueness equal or greater (CCI > 0.61) for lower molars on the supra-gingival edge for mesial and lingual surfaces. The intra-oral yielded the same level for said edge on the vestibular surface and the distal had the least trueness of all terminal edges with both scanners (CCI < 0.60) (p >0.05). It may be concluded that the intra-oral scanner generated the highest trueness values of all assessed conditions and substantially higher on the supra-gingival edge. | eng |
dc.description.degreelevel | Especialización | spa |
dc.description.degreename | Especialista en prostodoncia | spa |
dc.description.sponsorship | Grupo de Investigación: Unidad de Investigación en Epidemiologia Clínica Oral UNIECLO | spa |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | instname:Universidad El Bosque | spa |
dc.identifier.reponame | reponame:Repositorio Institucional Universidad El Bosque | spa |
dc.identifier.repourl | repourl:https://repositorio.unbosque.edu.co | |
dc.identifier.uri | https://hdl.handle.net/20.500.12495/10149 | |
dc.language.iso | spa | |
dc.publisher.faculty | Facultad de Odontología | spa |
dc.publisher.grantor | Universidad El Bosque | spa |
dc.publisher.program | Especialización en prostodoncia | spa |
dc.rights | Atribución-NoComercial-CompartirIgual 4.0 Internacional | * |
dc.rights.accessrights | https://purl.org/coar/access_right/c_abf2 | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.local | Acceso abierto | spa |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | * |
dc.subject | Exactitud | spa |
dc.subject | Escáner intraoral | spa |
dc.subject | Escáner extraoral | spa |
dc.subject | Línea terminal | spa |
dc.subject | Diente adyacente | spa |
dc.subject | Molar inferior | spa |
dc.subject.keywords | Trueness | spa |
dc.subject.keywords | Intra-oral scanner | spa |
dc.subject.keywords | Terminal edge | spa |
dc.subject.keywords | Adjacent tooth | spa |
dc.subject.keywords | Lower molar | spa |
dc.subject.keywords | Extra-oral scanner | spa |
dc.subject.nlm | WU 500 | |
dc.title | Exactitud de las imágenes digitales obtenidas por dos métodos de impresión dental- escáner extraoral [Ineos x5®] e intraoral [Cerec primescam®] - en molares inferiores con preparación para corona completa con dientes adyacentes | spa |
dc.title.translated | Trueness of digital images obtained with two methods of dental impressions – extra-oral scanner (Ineos x5®) and intra-oral (Cerec primescam®) – of lower molars with preparation for full crown with adjacent teeth | spa |
dc.type.coar | https://purl.org/coar/resource_type/c_7a1f | |
dc.type.coarversion | https://purl.org/coar/version/c_970fb48d4fbd8a85 | |
dc.type.driver | info:eu-repo/semantics/bachelorThesis | |
dc.type.hasversion | info:eu-repo/semantics/acceptedVersion | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Especialización | spa |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- Exactitud de las imágenes digitales obtenidas por dos métodos de impresión dental- escáner extraoral [Ineos x5®] e intraoral [Cerec primescam®] - en molares inferiores con preparación para corona completa con dientes adyacentes
- Tamaño:
- 2.11 MB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Exactitud de las imágenes digitales obtenidas por dos métodos de impresión dental- escáner extraoral [Ineos x5®] e intraoral [Cerec primescam®] - en molares inferiores con preparación para corona completa con dientes adyacentes
Bloque de licencias
1 - 5 de 5
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 1.95 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción:
No hay miniatura disponible
- Nombre:
- REFERENCIAS BIBLIOGRAFICAS.docx
- Tamaño:
- 19.64 KB
- Formato:
- Microsoft Word XML
- Descripción:
- Referencias bibliográficas
No hay miniatura disponible
- Nombre:
- CARTA AUTORIZACION DIVULGACION REPOSITORIO_Benavides_Ramirez_Carlos_Giovanny_2023.pdf
- Tamaño:
- 1.23 MB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Carta autorización
No hay miniatura disponible
- Nombre:
- FORMATO INFORMACION DIVULGACION REPOSITORIO Benavides_Ramirez_Carlos_Giovanny_2023.pdf
- Tamaño:
- 991 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Formato de información
No hay miniatura disponible
- Nombre:
- Acta trabajo de grado-Benavides_Ramirez_Carlos_Giovany_2023.pdf
- Tamaño:
- 305.09 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Acta de aprobación