dc.date.issued2020
dc.description.abstractEl zirconio es una cerámica policristalina utilizada para restauraciones libres de metal. Esta no posee matriz vítrea, por tanto, los procedimientos de cementación con previo acondicionamiento ácido no son efectivos. Actualmente, se cuentan con distintos tipos de agentes cementantes para estas restauraciones con imprimadores ricos en 10 MDP que junto con el uso de la microabrasión de las superficies permiten una retención mecánica y una unión físico-química estable en el tiempo. Recientemente, se han propuesto nuevos cementos basados en vidrios bioactivos, los cuales presentan como beneficio adicional, el cierre de brechas marginales a través de la remineralización de la dentina. Sin embargo, existen pocos estudios que evalúen su resistencia adhesiva y la comparen con los sistemas de cementación ricos en MDP. Por tanto, el objetivo de este estudio fue evaluar la fuerza adhesiva al zirconio de 2 cementos bioactivos: "Ceramir®" y Theracem®. En este estudio experimental in vitro se usó una muestra probabilística de 30 muestras por cada uno de los tres grupos evaluado: los dos cementos biactivos y un cemento control Relyx™ Ultimate. Cada unidad muestral consistió en un cilindro de 1mm H X 0.5mm de diámetro cementado a láminas maquinadas de zirconio translucido de 1.5mm[h] X 1.2mm[L] X 5mm [W] arenadas con óxido de aluminio de 50 micras. Para la fabricación de cada cilindro se utilizó como molde un tubo de Tygon® Las muestras serán sometidas a proceso de termociclado (5000 ciclos de 1 minuto cada uno a temperaturas de 5 a 55°) y posteriormente a la prueba de resistencia adhesiva en la máquina universal de pruebas. Los datos serán expresados en MPa serán analizados descriptivamente mediante medidas de tendencia central y de dispersión. Para determinar si los datos siguen una distribución normal se utilizará la prueba Shapiro-Wilk,dependiendo de la normalidad de los datos se usará la prueba de ANOVA a una vía o de Kruskar-Wallis. En resultados parciales encontró que el 23.33 % del grupo Ceramir se perdió durante el fraguado del cemento y 76.66% durante el retiro del tygon. En los grupos Theracem y Relyx Ultimate no se observaron perdidas de muestras durante la fabricación.spa
dc.description.abstractenglishZirconium is a polycrystalline ceramic used for metal-free restorations because it has no vitreous matrix, so cementation procedures with previous acid conditioning are not effective. There are different agents for said restorations rich in 10MDP primers, which along with micro-abrasion of the surfaces allow a stable mechanical retention and physical-chemical union. New cements based on bio-active glass have been proposed which present the filling of marginal gaps by re-mineralising the dentin. However, there are few studies which evaluate its adhesive strength and compare it with systems rich in MDP so the aim of this study was to do so with two bio-active cements: Ceramir®" y Theracem® on Zirconium. A probabilistic trial of 30 samples for each of the three evaluation groups was used: two bio-active cements and the control Relyx™ Ultimate. Each consisted of a 1 mm cylinder H X 0.5 mm cemented to transparent 1.5mm[h] X 1.2mm[L] X 5mm [W] zirconium machined plates sanded with 50 micron aluminium oxide. A tube of Tygon® was used for the fabrication of the cylinders and the samples will be subject to a thermocycled process (5000 one-minute cycles at temperatures between 5 ˚ and 55 ˚) after which the strength trial in the universal testing machine will be carried out. Results will be expressed in MPa and analysed descriptively with central tendency and dispersion measurements. The Shapiro-Wilk test will be used to determine if data follows a normal distribution and one-way ANOVA or Kruskar-Wallis tests depending on the normality of data. Partial results showed that 23.33% of the Ceramir group was lost during setting and 76.66% during the Tygon removal. No losses were reported during fabrication with the Theracem and Relyx Ultimate groups.eng
dc.description.degreelevelEspecializaciónspa
dc.description.degreenameEspecialista en prostodonciaspa
dc.format.mimetypeapplication/pdf
dc.identifier.instnameinstname:Universidad El Bosquespa
dc.identifier.reponamereponame:Repositorio Institucional Universidad El Bosquespa
dc.identifier.repourlrepourl:https://repositorio.unbosque.edu.co
dc.identifier.urihttps://hdl.handle.net/20.500.12495/8380
dc.language.isospa
dc.publisher.facultyFacultad de Odontologíaspa
dc.publisher.grantorUniversidad El Bosquespa
dc.publisher.programEspecialización en prostodonciaspa
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 International*
dc.rights.accessrightshttps://purl.org/coar/access_right/c_abf2
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommons2020-08
dc.rights.localAcceso abiertospa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectFuerza adhesivaspa
dc.subjectCementos de resinaspa
dc.subjectCementos bioceramicosspa
dc.subjectAgentes cementantesspa
dc.subjectCementos resinososspa
dc.subjectZirconiospa
dc.subject.keywordsResin cementsspa
dc.subject.keywordsBio-ceramic cementsspa
dc.subject.keywordsCementing agentsspa
dc.subject.keywordsResinous cementsspa
dc.subject.keywordsZirconiumspa
dc.subject.keywordsAdhesive strengthspa
dc.subject.nlmWU 500
dc.titleEvaluación de la fuerza adhesiva al zirconio de 2 cementos bioactivos: "Ceramir®" y Theracem ®. Resultados preliminaresspa
dc.title.translatedEvaluation of the adhesive strength on zirconium of two bio-active cements: Ceramir® and Theracem®. Preliminary resultsspa
dc.type.coarhttps://purl.org/coar/resource_type/c_7a1f
dc.type.coarversionhttps://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.driverinfo:eu-repo/semantics/bachelorThesis
dc.type.hasversioninfo:eu-repo/semantics/acceptedVersion
dc.type.localTesis/Trabajo de grado - Monografía - Especializaciónspa

Archivos

Bloque original
Mostrando 1 - 3 de 3
Cargando...
Miniatura
Nombre:
Arango_Anaya_Gerson_Fabian_2020.pdf
Tamaño:
1.21 MB
Formato:
Adobe Portable Document Format
Descripción:
Cargando...
Miniatura
Nombre:
Arango_Anaya_Gerson_Fabian_2020_anexos.pdf
Tamaño:
245.49 KB
Formato:
Adobe Portable Document Format
Descripción:
Cargando...
Miniatura
Nombre:
Arango_Anaya_Gerson_Fabian_2020_carta_de_autorización.pdf
Tamaño:
638.69 KB
Formato:
Adobe Portable Document Format
Descripción:
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: