dc.description.abstract | La espirometría constituye el examen básico en la evaluación de la función pulmonar para fines diagnósticos, terapéuticos y de investigación, permitiendo reconocer las limitaciones obstructivas y restrictivas. Existen estandarizaciones internacionales para su realización e interpretación, recomendándose utilizar valores normales de referencia de la población a estudiar. OBJETIVOS: 1) Determinar valores espirométricos normales en la población de niños escolares sanos asistentes al Colegio Gimnasio San José en la ciudad de Bogotá, 2) Establecer correlación de resultados espirométricos con edad, sexo, talla y estado nutricional de los niños sanos elegidos, 3) Determinar si son los valores de referencia internacionales de curvas flujo volumen iguales para nuestra población de niños sanos entre 6 y 16 años en la ciudad de Bogota. MATERIALES Y METODOS: es un estudio descriptivo observacional, donde se incluyeron en el estudio 524 niños entre las edades de 6 a 16 años, de los cuales 90 no cumplieron los criterios de inclusión quedando finalmente 434, quienes previo consentimiento informado fueron pesados, tallados y se les realizo la espirometría, donde se evaluó principalmente: CVF (capacidad vital forzada), VEF1 (volumen espiratorio forzado en el primer minuto), relación VEF 1/CVF, FEP (flujo espiratorio pico), se cruzaron las variables obteniendo promedios según edad, talla, peso, genero y percentil de edad/talla. RESULTADOS: el grupo de mayor numero de niños sin importar el genero fue el de 15 años, la mayoría obtuvieron valores mayores a los predichos por el programa del espirómetro en CVF, VEF1 tanto en niños como en niñas, en el PEF se encontró tendencia a la disminución con respecto al valor de la media, pero todos por encima del 80% del valor de la media. En la relación VEF1/CVF se encontró que al promediar todos los datos tanto de niños y niñas todos los valores fueron superiores al 80 % menos en un solo grupo que era representado por 1 niña en la que reporto 0.72. Al distribuirse género se presentaron datos variados, algunos con valores mayores en niños y otros en niñas. CONCLUSIONES: encontramos diferencias de mediciones de comparación de espirometría con respecto a datos obtenidos de poblaciones diferentes a Colombia; hasta ahora es el intento mas grande en tratar de obtener dichas diferencias y estandardización de valores de espirometría en Colombia; se debe aumentar el tamaño de la muestra y volver el estudio multicéntrico y obtener datos aplicables a nivel del distrito capital | spa |
dc.description.abstractenglish | Spirometry is the most common of the Pulmonary Function Tests, measuring lung function with diagnostic and therapeutic purposes such as when conducting research and epidemiological studies. And allow to detect obstructive and restrictive abnormalities. There are international standards for performance and achievement of spirometry and it is recommended to use normal values of reference about the population who is going to be studied. Objectives: 1) to determine normal spirometric values in healthy school childrens who came to the Gymnasium San Jose School in Bogotá city. 2) to establish the relation between the spirometric values and age, gender, height and nutritional status in the population of the study.3) to determine if the international reference values of the volumeflow waveforms are the same to our population of healthy children between 6-16 years old in Bogotá city. Materials and methods. This is an observational descriptive study, five hundred and twenty four patients where included between 6-16 years old of whom 90 doesn’t meet the inclusion criteria. 434 patient previous inform consent where weighted, measure, and a spirometry was made to achieve CVF (vital forced capacity), VEF1 (forced expiratory volume in the first second), VEF1/CVF relation, PEF (peak expiratory flow). Whe cross covariates finding age, height, tall gender and age/height percentile. Results: The group of major number of children without importing gender was that of 15 years, the majority they obtained values bigger than the predicted in CVF, VEF1, in the PEF the opposite was found in children and in girls. The relation VEF1/CVF was superior to 80 % in all the children fewer 1 girl. About sex data trhe distributed they presented varied, some information with major values in children and others in girls. Conclusions: there are clear differences of measurements of comparison of spirometry with regard to information obtained of populations different to Colombia; Still now it is the biggest attempt in obtain the above mentioned differences and standardization of values of spirometry in Colombia; it is necessary to increase the size of the sample and turn the multicentral study and obtain information applicable to national level. | eng |
dc.description.degreelevel | Especialización | spa |
dc.description.degreename | Especialista en neumología pediátrica | spa |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | instname:Universidad El Bosque | spa |
dc.identifier.reponame | reponame:Repositorio Institucional Universidad El Bosque | spa |
dc.identifier.repourl | repourl:https://repositorio.unbosque.edu.co | |
dc.identifier.uri | https://hdl.handle.net/20.500.12495/6120 | |
dc.language.iso | spa | |
dc.publisher.faculty | Facultad de Medicina | spa |
dc.publisher.grantor | Universidad El Bosque | spa |
dc.publisher.program | Especialización en neumología pediátrica | spa |
dc.rights | Attribution-NonCommercial-ShareAlike 4.0 International | * |
dc.rights.accessrights | https://purl.org/coar/access_right/c_abf2 | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | 2007-01 | |
dc.rights.local | Acceso abierto | spa |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | * |
dc.subject | Espirometría | spa |
dc.subject | Valores normales | spa |
dc.subject | Niños | spa |
dc.subject | Curva flujo volumen | spa |
dc.subject.decs | Espirometría | spa |
dc.subject.decs | Pruebas de función respiratoria | spa |
dc.subject.decs | Valores de referencia | spa |
dc.subject.keywords | Spirometry | spa |
dc.subject.keywords | Normal values | spa |
dc.subject.keywords | Children | spa |
dc.subject.keywords | Curls flow volume | spa |
dc.subject.nlm | WS280 | spa |
dc.title | Determinación de valores normales en curva flujo volumen en niños sanos de un colegio en la ciudad de Bogotá | spa |
dc.title.translated | Determination of normal values in flow-volume curve in healthy children from a school in the city of Bogotá | spa |
dc.type.coar | https://purl.org/coar/resource_type/c_7a1f | |
dc.type.coarversion | https://purl.org/coar/version/c_970fb48d4fbd8a85 | |
dc.type.driver | info:eu-repo/semantics/bachelorThesis | |
dc.type.hasversion | info:eu-repo/semantics/acceptedVersion | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Especialización |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- León_Villanueva_Armando_2007.pdf
- Tamaño:
- 303.48 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
Bloque de licencias
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: