Comportamiento mecánico de la prótesis parcial fija en disilicato de litio sobre pilares con periodonto normal y disminuido: análisis de elementos finitos. Fase modelamiento

dc.contributor.advisorTamayo Muñoz, Martha Cecilia
dc.contributor.advisorLuna Angel, Luis Eduardo
dc.contributor.advisorRíos Linares, Ricardo Augusto
dc.contributor.advisorSepúlveda Ortega, Sandra Milena
dc.contributor.authorAriza Martínez, Stephanye
dc.date.accessioned2020-05-19T16:56:24Z
dc.date.available2020-05-19T16:56:24Z
dc.date.issued2018
dc.description.abstractEl objetivo de este proyecto fue evaluar la concentración de tensiones generados por una prótesis parcial fija [PPF] de canino a segundo premolar superior fabricada en disilicato de litio inyectado soportada por dientes con periodonto sano y por dientes con periodonto disminuido a través del análisis de elementos finitos. Se realizó una búsqueda estructurada de literatura sobre estudios de biomecánica en PPF con disislicato de Litio, a partir de la cual se estructuro una base con los datos utilizados en los estudios: modulo elástico, radio de Poisson y resistencia flexural del Disilicato de Litio. Los mismos datos para los tejidos dentales fueron tomados de estudios previos realizados en la Universidad. La depuración de estos datos se realizó matemáticamente utilizando la moda con sus intervalos modales. A partir de estos datos se estructuraron 1521 matrices de datos combinados de las cuales se escogieron tres matrices que cumplieran con los siguientes criterios: una cuyos datos de módulos elásticos, resistencia flexural y radio de Poisson del Disilicato de Litio fueran los que más frecuentemente se reportaran en la literatura, otra matriz con los valores más altos reportados en las bases de datos y por último se eligió la matriz de los datos que reporta la casa comercial de material Disilicato de Litio. Para facilitar el modelamiento de la PPF, se hicieron las preparaciones de los dientes pilares 13 y 15 sobre un modelo de ivorina que posteriormente fue digitalizado mediante el escáner multitalento inEos X5 – Sirona. A partir este modelo se diseñó digitalmente la PPF y sus imágenes fueron transferidas al software ANSYS WORKBENCH 18.0, en el cual se realizó el modelamiento para el análisis biomecánico con elemento finito.spa
dc.description.abstractenglishThe aim of this project was to evaluate by means of finite element analysis the concentration of tensions generated by a partially-fixed prosthesis (PFP) from the maxillary canine to the second premolar fabricated with injected lithium disilicate, supported by teeth with healthy periodontium and teeth with reduced periodontium. A structured literature search was carried out regarding biomechanical studies of PFP with lithium disilicate, from which a database was structured with the data used in the studies: Poisson’s ratio and lithium disilicate flex resistance. The same data for dental tissues were taken from previous studies carried out at the university. Data depuration was figured mathematically using a mode with its mode intervals. 1521 matrices of combined data were structured and three which complied with the following guidelines were chosen: one whose elasticity modules, flex resistance and Poisson’s ratio of the disilicate were most frequently reported; one with the highest reported values of the database; one with the data from the developer of lithium disilicate. Preparation of 13 and 15 pillar teeth were cast on an ivorine model which was digitised using the inEos X5 – Sirona multitalent scanner in order to facilitate PFP modelling. PFP was digitally designed from this model and its images were transferred to the ANSYS WORKBENCH 18.0 software where the biomechanical analysis with finite element modelling was developed.eng
dc.description.degreelevelEspecializaciónspa
dc.description.degreenameEspecialista en prostodonciaspa
dc.format.mimetypeapplication/pdf
dc.identifier.instnameinstname:Universidad El Bosquespa
dc.identifier.reponamereponame:Repositorio Institucional Universidad El Bosquespa
dc.identifier.repourlrepourl:https://repositorio.unbosque.edu.co
dc.identifier.urihttps://hdl.handle.net/20.500.12495/2967
dc.language.isospa
dc.publisher.facultyFacultad de Odontologíaspa
dc.publisher.grantorUniversidad El Bosquespa
dc.publisher.programEspecialización en prostodonciaspa
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 International*
dc.rights.accessrightshttps://purl.org/coar/access_right/c_abf2
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.creativecommons2018-07
dc.rights.localAcceso abiertospa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectAnálisis de elemento finitospa
dc.subjectPrótesis parcial fijaspa
dc.subjectDisilicato de litiospa
dc.subject.decsPrótesis e implantesspa
dc.subject.decsDentadura parcialspa
dc.subject.keywordsFinite element analysisspa
dc.subject.keywordsPartially-fixed prosthesesspa
dc.subject.keywordsLithium disilicatespa
dc.subject.nlmWU 500
dc.titleComportamiento mecánico de la prótesis parcial fija en disilicato de litio sobre pilares con periodonto normal y disminuido: análisis de elementos finitos. Fase modelamientospa
dc.title.translatedMechanical behaviour ofthe partially-fixed prosthesis in lithium di-silicate on pillars with normal and reduced periodontium. Finite element analysis. Modelling pasespa
dc.type.coarhttps://purl.org/coar/resource_type/c_7a1f
dc.type.coarversionhttps://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.driverinfo:eu-repo/semantics/bachelorThesis
dc.type.hasversioninfo:eu-repo/semantics/acceptedVersion
dc.type.localTesis/Trabajo de grado - Monografía - Especializaciónspa

Archivos

Bloque original
Mostrando 1 - 2 de 2
Cargando...
Miniatura
Nombre:
Ariza_Matínez_Stephanye_2018.pdf
Tamaño:
1.61 MB
Formato:
Adobe Portable Document Format
Descripción:
No hay miniatura disponible
Nombre:
Ariza_Matínez_Stephanye_2018_Carta_autorizacion.pdf
Tamaño:
2.16 MB
Formato:
Adobe Portable Document Format
Descripción:
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descripción: