Modelo de interoperabilidad de datos entre dispositivos biomédicos y sistemas de información de pacientes en las unidades de cuidados intensivos, utilizando un servidor FHIR
dc.contributor.advisor | Portilla Vicuña, Fernando Antonio | |
dc.contributor.author | Rodriguez Correa, Daniela | |
dc.contributor.orcid | Rodriguez Correa, Daniela | |
dc.date.accessioned | 2022-10-26T19:53:57Z | |
dc.date.available | 2022-10-26T19:53:57Z | |
dc.date.issued | 2022 | |
dc.description.abstract | La Unidades de Cuidados Intensivos generan un sin número de información y/o datos, que en su mayoría son descartados y no se lleva un registro de estos, especialmente frente a las enfermedades cardiovasculares, las cuales se han convertido en una de las mayores causas de morbilidad y/o mortalidad de la era moderna. Debido a lo anterior es importante desarrollar herramientas que permiten el aprovechamiento de esta información, para lo cual se diseñó un modelo de interoperabilidad en el cual se realizó la revisión de la información proporcionada por los equipos biomédicos, los parámetros y el impacto de este dispositivo a nivel clínico. El monitor de signos vitales fue el equipo elegido para el desarrollo del proyecto. Posteriormente se hace un análisis de los parámetros fisiológicos básicos que mide este equipo, se toma como referencia la presión arterial sistólica, presión arterial diastólica, saturación de oxígeno, pulso y frecuencia cardiaca. Se utilizo OpenICE como simulador del equipamiento biomédico, posteriormente se realizó un análisis de la mensajería y de los datos, identificando un mensaje HL7 V2 tipo ORU; posteriormente bajo este estándar y teniendo en cuenta cada uno de los segmentos y requisitos de esté, se procedió a diseñar un código en Python, el cual tenia como objetivo generar mensajes ORU, con valores aleatorios para los parámetros fisiológicos, y enviar esta información a Mirth Connect, el cual fue el bus de interoperabilidad seleccionado, para la recepción de los datos, transformación de la mensajería de un estándar HL7.V2 a un estándar FHIR y transmisión a un servidor FHIR. Finalmente se visualizó la información bajo un estándar HL7 FHIR, en el servidor de prueba. El proyecto se desarrolló utilizando las herramientas que se pueden encontrar con las Tecnologías de la Información y Comunicaciones (TIC), las cuales se pueden aplicar a todas las necesidades que tiene el sector salud actualmente. Los estándares de interoperabilidad permiten la integración de datos biomédicos para el uso y aprovechamiento, por parte del cuerpo médico y/o asistencial en la toma de decisiones; teniendo en cuenta lo anterior fue necesario garantizar que la información cumpliera con la característica para utilizar un formato estándar que pudiera ser leído y almacenado por cualquier tecnología. | spa |
dc.description.abstractenglish | The Intensive Care Units generate an endless number of information and/or data, which are mostly discarded and a record of these is not kept, especially in the face of cardiovascular diseases, which have become one of the main causes of death. morbidity and/or mortality of the modern era. Due to the above, it is important to develop tools that allow the use of this information, for which an interoperability model was developed in which the information provided by the biomedical equipment, the parameters and the impact of this device were reviewed. clinical level. The vital signs monitor was the equipment chosen for the development of the project. Subsequently, an analysis of the basic physiological parameters measured by this equipment is made, taking as reference the systolic blood pressure, diastolic blood pressure, oxygen saturation, pulse and heart rate. OpenICE was used as a simulator of the biomedical equipment, later an analysis of the messaging and data was carried out, identifying an HL7 V2 ORU type message; Subsequently, under this standard and taking into account each of its segments and requirements, a Python code was designed, which had the objective of generating ORU messages, with random values for the physiological parameters, and sending this information to Mirth Connect, which was the selected interoperability bus, for data reception, messaging transformation from an HL7.V2 standard to an FHIR standard and transmission to an FHIR server. Finally, the information was displayed under an HL7 FHIR standard, on the test server. The project will be implemented using the tools that can be found with Information and Communication Technologies (ICT), which can be applied to all the needs that the health sector currently has. Interoperability standards allow the integration of biomedical data for the use and exploitation by the medical and/or healthcare body in decision-making; Taking into account the above, it was necessary to guarantee that the information complied with the characteristic to use a standard format that could be read and stored by any technology. | eng |
dc.identifier.uri | https://hdl.handle.net/20.500.12495/9233 | |
dc.language.iso | spa | |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.accessrights | https://purl.org/coar/access_right/c_abf2 | |
dc.rights.local | Acceso abierto | spa |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | * |
dc.subject | Interoperabilidad | spa |
dc.subject | Unidad de Cuidados Intensivos | spa |
dc.subject | Monitor de signos vitales | spa |
dc.subject | HL7 | spa |
dc.subject | FHIR | spa |
dc.subject | Parámetros fisiológicos | spa |
dc.subject | Mirth Connect | spa |
dc.subject.keywords | Mirth Connect | spa |
dc.subject.keywords | HL7 | spa |
dc.subject.keywords | FHIR | spa |
dc.subject.keywords | Interoperability | spa |
dc.subject.keywords | Intensive Care Unit | spa |
dc.subject.keywords | Vital Sign Monitor | spa |
dc.subject.keywords | Physiological Parameters | spa |
dc.title | Modelo de interoperabilidad de datos entre dispositivos biomédicos y sistemas de información de pacientes en las unidades de cuidados intensivos, utilizando un servidor FHIR | spa |
dc.title.translated | Interoperability model of data between biomedical devices and information systems of patients in care units intensive, using a FHIR server | spa |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- DOCUMENTO PROYECTO DE GRADO DANIELA RODRIGUEZ CORREA .pdf
- Tamaño:
- 2.42 MB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Modelo de interoperabilidad de datos entre dispositivos biomédicos y sistemas de información de pacientes en las unidades de cuidados intensivos, utilizando un servidor FHIR
Bloque de licencias
1 - 2 de 2
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 1.95 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción:
No hay miniatura disponible
- Nombre:
- Carta de autorizacion de contenidos.pdf
- Tamaño:
- 1.06 MB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Carta de autorización