Impacto de la liposucción asistida por ultrasonido sobre el valor de hemoglobina y hematocrito post-operatorio en cirugía de contorno corporal en pacientes sanos
dc.contributor.advisor | Avellaneda Molano, Minyor | |
dc.contributor.advisor | Gómez, Carlos | |
dc.contributor.advisor | Méndez Ordoñez, Erika Marcela | |
dc.contributor.author | Aguana Monzón, Carlos David | |
dc.contributor.author | Díaz Rengifo, Cristhian Camilo | |
dc.coverage.spatial | Bogotá (Colombia) | spa |
dc.coverage.temporal | 2018 - 2020 | spa |
dc.date.accessioned | 2022-08-22T23:43:24Z | |
dc.date.available | 2022-08-22T23:43:24Z | |
dc.date.issued | 2020 | |
dc.description.abstract | Objetivo: Determinar asociación directa entre el valor de hemoglobina post-operatorio y la realización de liposucción asistida por ultrasonido en población colombiana. Metodología: El presente estudio de tipo corte transversal con análisis de las variables de bases de datos existentes para evaluar la creación entre estas. Se realiza una recopilación de datos en las bases de datos del Centro Médico NUARA®, extrayendo un total de 103 paciente sanos sometidos a cirugía de contorno corporal con liposucción operados por el Dr. Minyor Avellaneda en la ciudad de Bogotá/Colombia, en un periodo de 2 años comprendidos entre el enero de 2018 a marzo de 2020. Posterior a la aplicación de los criterios de selección se obtuvo una muestra de 77 pacientes en los que se evaluó la relación entra la aplicación de liposucción asistida por ultrasonido y el descenso de la hemoglobina post-operatoria a las 24 horas. Resultados: Se dividió la población en un grupo control de 39 pacientes, al cual se le realizo liposucción sin ultrasonido y un grupo expuesto de 38 pacientes, al que se le realizo ultrasonido como coadyuvante de la liposucción, para un total de 77 pacientes sometidos a cirugía de contorno corporal con liposucción asociada. A todos los pacientes se les midió el valor de hemoglobina pre y post-operatoria a las 24 horas, para luego calcular el valor de hemoglobina diferencial, entendiéndose este como el sustrato de la resta entre la hemoglobina pre y post-operatoria, diviendolo así en dos grupo, el grupo 1 con hemoglobina < 3 gr/dL y el grupo 2 ≥ 3 gr/dL. No se encontró diferencia estadísticamente significativa en los valores de hemoglobina diferencial entre los pacientes sometidos a liposucción asistida por ultrasonido y los que no con un valor de p = 0,819. Conclusiones: La liposucción asistida por ultrasonido ha mostrado múltiples beneficios en la disminución de complicaciones post-operatorias de los pacientes, entre las cuales se encuentra una disminución del sangrado en múltiples estudios. Sin embargo en el presente estudio no se establece relación directa entre la implementación de esta tecnología y la disminución de los valores de hemoglobina post-operatoria en población colombiana. | spa |
dc.description.abstractenglish | Objective: To determine a direct association between the post-operative hemoglobin value and the performance of ultrasound-assisted liposuction in the Colombian population. Methodology: The present cross-sectional study is analyzing the variables of existing databases to evaluate the creation between them. databases of the NUARA® Medical Center has been collected, obtaining a total of 103 healthy patients undergoing body contouring surgery with liposuction operated by Dr. Minyor Avellaneda in Bogotá / Colombia, in 2 years period from January 2018 to March 2020. After applying the selection criteria, a sample of 77 patients was isolated in which the relationship between the application of ultrasound-assisted liposuction and the decrease in 24 hours post-operative hemoglobin was evaluated. Results: The population was divided into a control group of 39 patients, who underwent liposuction without ultrasound, and an exposed group of 38 patients, who underwent ultrasound as an adjunct to liposuction, a total of 77 patients of body contouring surgery with associated liposuction was evaluated. In all patients, the pre-operative and 24 hours postoperative hemoglobin value was measured, and then the differential hemoglobin value was calculated, understanding this as the result of the subtraction between pre and postoperative hemoglobin, thus dividing it into two groups, group 1 with hemoglobin < 3 g / dL and group 2 ≥ 3 g / dL. No statistically significant difference was found in differential hemoglobin values between patients who underwent ultrasound-assisted liposuction and those who did not, with a value of p = 0.819. Conclusions: Ultrasound-assisted liposuction has shown multiple benefits in reducing post-operative complications in patients, among which is a decrease in bleeding in multiple studies. However, in the present study, no direct relationship is established between the implementation of this technology and the decrease in postoperative hemoglobin values in Colombian population. | eng |
dc.description.degreelevel | Especialización | spa |
dc.description.degreename | Especialista en cirugía plástica reconstructiva y estética | spa |
dc.description.sponsorship | Centro Médico NUARA | spa |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | instname:Universidad El Bosque | spa |
dc.identifier.reponame | reponame:Repositorio Institucional Universidad El Bosque | spa |
dc.identifier.repourl | repourl:https://repositorio.unbosque.edu.co | |
dc.identifier.uri | https://hdl.handle.net/20.500.12495/8833 | |
dc.language.iso | spa | |
dc.publisher.faculty | Facultad de Medicina | spa |
dc.publisher.grantor | Universidad El Bosque | spa |
dc.publisher.program | Especialización en cirugía plástica reconstructiva y estética | spa |
dc.rights | Attribution-NonCommercial-ShareAlike 4.0 International | * |
dc.rights.accessrights | https://purl.org/coar/access_right/c_abf2 | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.creativecommons | 2020-11-12 | |
dc.rights.local | Acceso abierto | spa |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | * |
dc.subject | Liposucción asistida por ultrasonido | spa |
dc.subject | Hemoglobina | spa |
dc.subject | Sangrado post-operatorio | spa |
dc.subject | Seguridad en liposucción | spa |
dc.subject | Cirugía de contorno corporal | spa |
dc.subject.keywords | Ultrasound-assisted liposuction | spa |
dc.subject.keywords | Hemoglobin | spa |
dc.subject.keywords | Postoperative bleeding | spa |
dc.subject.keywords | Liposuction safety | spa |
dc.subject.keywords | Body contouring surgery | spa |
dc.subject.nlm | WO 600 | |
dc.title | Impacto de la liposucción asistida por ultrasonido sobre el valor de hemoglobina y hematocrito post-operatorio en cirugía de contorno corporal en pacientes sanos | spa |
dc.title.translated | Impact of ultrasound-assisted liposuction on post-operative hemoglobin value in body contour surgery | spa |
dc.type.coar | https://purl.org/coar/resource_type/c_7a1f | |
dc.type.coarversion | https://purl.org/coar/version/c_ab4af688f83e57aa | |
dc.type.driver | info:eu-repo/semantics/bachelorThesis | |
dc.type.hasversion | info:eu-repo/semantics/acceptedVersion | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Especialización | spa |
Archivos
Bloque original
1 - 3 de 3
Cargando...
- Nombre:
- Aguana_Monzón_Carlos_David_Díaz_Rengifo_Cristhian_Camilo_2021.pdf
- Tamaño:
- 846.35 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Impacto de la liposucción asistida por ultrasonido sobre el valor de hemoglobina y hematocrito post-operatorio en cirugía de contorno corporal en pacientes sanos
No hay miniatura disponible
- Nombre:
- Aguana_Monzón_Carlos_David_Díaz_Rengifo_Cristhian_Camilo_2021_Carta_de_autorización.pdf
- Tamaño:
- 925.06 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Carta de autorización
No hay miniatura disponible
- Nombre:
- Probatus Dres Carlos Aguana y Cristhian Diaz.pdf
- Tamaño:
- 123.92 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
- Probatus
Bloque de licencias
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: