Spontaneous rupture of chemotherapy catheter diagnosed using chest X-ray oblique projections: An interventional radiology approach

dc.contributor.authorHerrera Ortiz, Andrés Felipe
dc.contributor.authorPinzón Valderrama, Bibiana
dc.contributor.authorRivero, Oscar Mauricio
dc.contributor.authorTorres, David Fernando
dc.contributor.authorCardona, José David
dc.contributor.authorTakegami, Mayumi Tanaka
dc.contributor.authorVillalobos Luna, Jesús Leonardo
dc.contributor.authorGutierrez, Laura Camila
dc.contributor.authorQuintero Cabrera, Nicolás
dc.contributor.authorQuiroz Alfaro, Alejandro José
dc.date.accessioned2023-02-20T15:08:19Z
dc.date.available2023-02-20T15:08:19Z
dc.date.issued2023
dc.description.abstractLos sistemas de puerto venoso central totalmente implantados se utilizan ampliamente para acceder a las venas centrales de los pacientes que necesitan un tratamiento a largo plazo. Estos dispositivos presentan bajas tasas de complicaciones y se utilizan habitualmente para administrar medicamentos como agentes quimioterapéuticos. La rotura espontánea de un segmento del catéter es una complicación mecánica infrecuente, que suele diagnosticarse tardíamente y presentar complicaciones. Presentamos un caso de rotura espontánea de un catéter de quimioterapia diagnosticado mediante un novedoso abordaje a través de proyecciones oblicuas en radiografías de tórax y extraído con éxito mediante un abordaje endovascular.spa
dc.description.abstractenglishTotally implanted central venous port systems are widely used to access central veins for patients needing long-term therapy. These devices have low rates of complications and are commonly used to administer medications like chemotherapeutic agents. Spontaneous rupture of a catheter segment is a rare mechanical complication, usually belatedly diagnosed and presenting with complications. We present a case of a spontaneously ruptured chemotherapy catheter diagnosed using a novel approach via oblique projections on chest X-rays and successfully removed using an endovascular approach.eng
dc.format.mimetypeapplication/pdf
dc.identifier.doihttps://doi.org/10.1016/j.radcr.2022.10.055
dc.identifier.instnameinstname:Universidad El Bosquespa
dc.identifier.issn1930-0433
dc.identifier.reponamereponame:Repositorio Institucional Universidad El Bosquespa
dc.identifier.repourlrepourl:https://repositorio.unbosque.edu.co
dc.identifier.urihttps://hdl.handle.net/20.500.12495/9996
dc.language.isoeng
dc.publisherElsevier Inc.spa
dc.publisherUniversity of Washingtonspa
dc.publisher.journalRadiology Case Reportsspa
dc.relation.ispartofseriesRadiology Case Reports, 1930-0433, 18, 1, January 2023, 349 - 352spa
dc.relation.urihttps://www.clinicalkey.es/#!/content/playContent/1-s2.0-S1930043322009256?returnurl=https:%2F%2Flinkinghub.elsevier.com%2Fretrieve%2Fpii%2FS1930043322009256%3Fshowall%3Dtrue&referrer=
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessrightshttps://purl.org/coar/access_right/c_abf2
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightsAcceso abierto
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectRotura de catéterspa
dc.subjectCatéter de quimioterapiaspa
dc.subjectTratamiento endovascularspa
dc.subjectRadiografía de tóraxspa
dc.subjectSíndrome de pinzamientospa
dc.subjectFractura del catéterspa
dc.subject.keywordsCatheter rupturespa
dc.subject.keywordsChemotherapy catheterspa
dc.subject.keywordsEndovascular treatmentspa
dc.subject.keywordsChest X-rayspa
dc.subject.keywordsPinch-off syndromespa
dc.subject.keywordsCatheter fracturespa
dc.titleSpontaneous rupture of chemotherapy catheter diagnosed using chest X-ray oblique projections: An interventional radiology approachspa
dc.title.translatedRotura espontánea de catéter de quimioterapia diagnosticada mediante proyecciones oblicuas de radiografía de tórax: Un enfoque de radiología intervencionistaspa
dc.type.coarhttps://purl.org/coar/resource_type/c_6501
dc.type.coarversionhttps://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.driverinfo:eu-repo/semantics/article
dc.type.hasversioninfo:eu-repo/semantics/publishedVersion
dc.type.localArtículo de revista

Archivos

Bloque original
Mostrando 1 - 1 de 1
Cargando...
Miniatura
Nombre:
1-s2.0-S1930043322009256.pdf
Tamaño:
1.4 MB
Formato:
Adobe Portable Document Format
Descripción:
Spontaneous rupture of chemotherapy catheter diagnosed using chest X-ray oblique projections: An interventional radiology approach
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.95 KB
Formato:
Item-specific license agreed upon to submission
Descripción:

Colecciones