Comparación biomecánica entre un sistema de fijación con clavos de kirschner cruzados frente a un nuevo sistema de fijación de clavos de kirschner con bloqueo externo (Junta H ®) en hueso animal
dc.contributor.advisor | Romero Barreto, Camilo José | |
dc.contributor.advisor | Sandoval Reyes, Julio | |
dc.contributor.author | Hernández Ramírez, Dallan Geller | |
dc.date.accessioned | 2021-03-24T20:34:10Z | |
dc.date.available | 2021-03-24T20:34:10Z | |
dc.date.issued | 2017 | |
dc.description.abstract | Objetivo: Determinar la resistencia al Ensayo de flexión de los constructos de clavos de Kirschner cruzados con bloqueo externo de 5 mm y de 10 mm o sin bloqueo externo en una osteotomía en metacarpiano de cerdo para definir si el bloqueo externo (junta H) ofrece mayor resistencia al fracaso. Métodos: Es un estudio Pseudo experimental donde se obtiene una muestra de 15 metacarpianos de cerdo que se osteotomizan y se distribuyen homogéneamente según sus tamaños en tres grupos de 5 muestras cada grupo. Un grupo se denomina cruzado en donde se fija la osteotomía con clavos cruzados de 1,2 mm otro se denomina bloqueado de 5 mm que además de fijar la osteotomía con clavos cruzados de 1,2 mm estos de fijan externamente con un bloqueo externos. Y el tercer grupo se denomina bloqueado de 10 mm en donde la osteotomía se fija igual que la anterior pero el bloqueo externo es de 10 mm. Estas muestras se evalúan en un ensayo de flexión en una maquina Instron pequeña, y se obtiene los resultados cuando la deformidad alcanza los 2 milímetros de flexión, se analizan los datos en Excel y se realiza evolución estadística básica, análisis de variables y pruebas de hipótesis Resultados: En promedio los clavos bloqueados 10 mm presentan mayor resistencia al fracaso en las pruebas de flexión pero este resultado en la prueba no logra ser concluyente dado que la muestra es escasa y las varianzas amplias. Conclusiones: Como resultado de este estudio se puede concluir que el bloqueo externo de los clavos de Kirschner para manejar fracturas de falanges y metacarpianos puede mejorar la resistencia al fracaso en flexión del constructo, pero es necesario realizar pruebas en humanos para definir si es factible con esta técnica suprimir el uso de férulas y de esta manera iniciar una movilidad y rehabilitación temprana. | spa |
dc.description.abstractenglish | Objective: To determine the resistance to the flexure test of the Kirschner nail constructs crossed with 5 mm and 10 mm external block or without external block in a pork metacarpal osteotomy to determine if the external block (H joint) increases Failure Resistance.. Methods: This is a Pseudo-experimental study where a sample of 15 pork metacarpals is obtained and osteotomized and homogeneously distributed according to their sizes in three groups of 5 samples per group. One group is denominated crusader in which the osteotomy is fixed with crossed nails of 1.2 mm another one is denominated locked of 5 mm that in addition to fix the osteotomy with crossed nails of 1.2 mm these of fix externally with an external blockade. And the third group is called a 10 mm block in which the osteotomy is set equal to the previous one but the external block is 10 mm. These samples are evaluated in a flexure test in a small Instron machine, and the results are obtained when the deformity reaches 2 mm of flexion, the data is analyzed in Excel and basic statistical evolution, variable analysis and hypothesis testing Results: On average the 10 mm locked nails present greater resistance to failure in the flexural tests but this result in the test does not manage to be conclusive since the sample is scarce and the variances are wide. Conclusions: As a result of this study, it can be concluded that external blockade of Kirschner nails to manage phalangeal and metacarpal fractures can improve resistance to failure in flexion of the construct, but it is necessary to perform tests in humans to define if feasible with this technique Suppress the use of splints and thus initiate early mobility and rehabilitation. | eng |
dc.description.degreelevel | Especialización | spa |
dc.description.degreename | Especialista en cirugía de mano | spa |
dc.format.mimetype | application/pdf | |
dc.identifier.instname | instname:Universidad El Bosque | spa |
dc.identifier.reponame | reponame:Repositorio Institucional Universidad El Bosque | spa |
dc.identifier.repourl | repourl:https://repositorio.unbosque.edu.co | |
dc.identifier.uri | https://hdl.handle.net/20.500.12495/5673 | |
dc.language.iso | spa | |
dc.publisher.faculty | Facultad de Medicina | spa |
dc.publisher.grantor | Universidad El Bosque | spa |
dc.publisher.program | Especialización en Cirugía de Mano | spa |
dc.rights | Atribución-NoComercial-CompartirIgual 4.0 Internacional | * |
dc.rights.accessrights | https://purl.org/coar/access_right/c_abf2 | |
dc.rights.accessrights | info:eu-repo/semantics/openAccess | |
dc.rights.local | Acceso abierto | spa |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-sa/4.0/ | * |
dc.subject.decs | Osteotomía -- Animales | spa |
dc.subject.decs | Clavos ortopédicos | spa |
dc.subject.decs | Experimentación animal | spa |
dc.subject.keywords | Kirschner Wires | spa |
dc.subject.keywords | Bone Wires | spa |
dc.subject.keywords | External Fixation Device | spa |
dc.subject.keywords | Closed Fracture Reduction | spa |
dc.subject.nlm | WE 830 | |
dc.title | Comparación biomecánica entre un sistema de fijación con clavos de kirschner cruzados frente a un nuevo sistema de fijación de clavos de kirschner con bloqueo externo (Junta H ®) en hueso animal | spa |
dc.type.coar | https://purl.org/coar/resource_type/c_7a1f | |
dc.type.coarversion | https://purl.org/coar/version/c_ab4af688f83e57aa | |
dc.type.driver | info:eu-repo/semantics/bachelorThesis | |
dc.type.hasversion | info:eu-repo/semantics/acceptedVersion | |
dc.type.local | Tesis/Trabajo de grado - Monografía - Especialización | spa |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- Hernández_Ramírez_Dallan_Geller_2017.pdf
- Tamaño:
- 736.46 KB
- Formato:
- Adobe Portable Document Format
- Descripción:
Bloque de licencias
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: