Influencia de las variaciones anatómicas de la constricción apical con la edad en la exactitud de los localizadores apicales: Resultados preliminares

dc.contributor.advisorAlzate Mendoza, Diana Carolina
dc.contributor.advisorOlaya Abril, Ana Carolina
dc.contributor.advisorGamboa Martínez, Luis Fernando
dc.contributor.authorAciego Lan, Yelitza
dc.contributor.authorMeneses Fiallos, Tania Fernanda
dc.contributor.authorMuñóz Guartan, Carolina Lizzeth
dc.contributor.authorVélez Bravo, Paúl Andrés
dc.date.accessioned2022-08-30T16:48:50Z
dc.date.available2022-08-30T16:48:50Z
dc.date.issued2022
dc.description.abstractAntecedentes: En endodoncia establecer la longitud de trabajo representa un papel importante para el resto de la terapia que incluye la instrumentación y obturación del conducto radicular, conocer la longitud de trabajo exacta es importante para que los procedimientos se realicen dentro de los límites anatómicos. Hasta la fecha no existen estudios que evalúen la precisión de los localizadores apicales en pacientes de diferentes grupos de edad para determinar si los cambios generados por la edad a nivel apical, dados por la aposición fisiológica de tejido mineralizado, influyen en la precisión de la medida de la longitud de trabajo determinada por el localizador apical. Objetivo: El objetivo de este estudio fue evaluar la precisión de los localizadores apicales en diferentes grupos de edad. Materiales y métodos: El presente estudio se realiza en el paciente por tratarse de un estudio experimental Ex Vivo. El procedimiento se realiza luego de la selección del diente a tratar utilizando los criterios de inclusión y exclusión y luego de la aceptación a participar por parte del paciente y firma del consentimiento informado. Los grupos de estudio de este trabajo de investigación son tres; grupo no1 (15-30 años), grupo no2 (31-45 años) y grupo no3 (mayores de 46 años). Se realiza la apertura, conductimetría y fijación de la lima dentro de la cavidad bucal (como primera parte del procedimiento) y posteriormente se realiza la extracción del diente seleccionado para posteriormente analizar las mediciones y realizar el estudio pertinente sobre la precisión de los localizadores apicales. Una vez completada la muestra, los dientes previamente tratados serán llevados a un centro radiológico para realizar las respectivas tomografías CBCT para su posterior análisis. Resultados: El resultado esperado de este estudio es encontrar que existe una diferencia significativa entre los dispositivos comparados, teniendo al Root ZX II como el localizador apical más preciso en los 3 grupos de edad con influencia de los cambios fisiológicos. Conclusión: Los localizadores apicales pueden determinar con precisión el límite de la constricción apical. Los cambios fisiológicos que ocurren a nivel del foramen con la edad podrían influir en la precisión de la medición de los localizadores apicales.spa
dc.description.abstractenglishBackground: In endodontics establishing the working length represents an important role for the rest of the therapy including root canal instrumentation and obturation, knowing the exact working length is important for procedures to be performed within anatomical limits. To date, there are no studies evaluating the accuracy of apical locators in patients of different age groups to determine whether age-related changes at the apical level, given by the physiological apposition of mineralized tissue, influence the accuracy of the working length measurement determined by the apical locator. Objective: The aim of this study was to evaluate the accuracy of apical locators in different age groups. Materials and methods: This study is performed on the patient because it is an Ex Vivo experimental study. The procedure is carried out after the selection of the tooth to be treated using the inclusion and exclusion criteria and after the patient accepts to participate and signs the informed consent form. The study groups for this research work are three: group 1 (15-30 years), group 2 (31-45 years) and group 3 (over 46 years). The opening, conductometry and fixation of the file inside the oral cavity (as the first part of the procedure) and then the extraction of the selected tooth is carried out in order to later analyze the measurements and carry out the pertinent study on the precision of the apical locators. Once the sample has been completed, the previously treated teeth will be taken to a radiological center to perform the respective CBCT scans for subsequent analysis. Results: The expected result of this study is to find that there is a significant difference between the devices compared, having the Root ZX II as the most accurate apical locator in the 3 age groups influenced by physiological changes. Conclusion: Apical locators can accurately determine the limit of apical constriction. Physiological changes occurring at the level of the foramen with age could influence the measurement accuracy of apical locators.eng
dc.description.degreelevelEspecializaciónspa
dc.description.degreenameEspecialista en endodonciaspa
dc.description.sponsorshipGrupo de investigación : Unidad de Investigación en Epidemiología Clínica Oral UNIECLOspa
dc.format.mimetypeapplication/pdf
dc.identifier.instnameinstname:Universidad El Bosquespa
dc.identifier.reponamereponame:Repositorio Institucional Universidad El Bosquespa
dc.identifier.repourlrepourl:https://repositorio.unbosque.edu.co
dc.identifier.urihttps://hdl.handle.net/20.500.12495/8911
dc.language.isospa
dc.publisher.facultyFacultad de Odontologíaspa
dc.publisher.grantorUniversidad El Bosquespa
dc.publisher.programEspecialización en endodonciaspa
dc.rightsAtribución-NoComercial-CompartirIgual 4.0 Internacional*
dc.rightsAtribución-NoComercial-CompartirIgual 4.0 Internacional*
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.accessrightshttps://purl.org/coar/access_right/c_abf2
dc.rights.localAcceso abiertospa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectPrecisiónspa
dc.subjectConstricción apicalspa
dc.subjectForamen apicalspa
dc.subjectLocalizador apicalspa
dc.subjectLongitud de trabajospa
dc.subject.keywordsAccuracyspa
dc.subject.keywordsApical constrictionspa
dc.subject.keywordsApical foramenspa
dc.subject.keywordsApex locatorspa
dc.subject.keywordsWorking lengthspa
dc.subject.nlmWU 230
dc.titleInfluencia de las variaciones anatómicas de la constricción apical con la edad en la exactitud de los localizadores apicales: Resultados preliminaresspa
dc.title.translatedInfluence of anatomical variations of apical constriction with age on the accuracy of apical locators: Preliminary resultsspa
dc.type.coarhttps://purl.org/coar/resource_type/c_7a1f
dc.type.coarversionhttps://purl.org/coar/version/c_ab4af688f83e57aa
dc.type.driverinfo:eu-repo/semantics/bachelorThesis
dc.type.hasversioninfo:eu-repo/semantics/acceptedVersion
dc.type.localTesis/Trabajo de grado - Monografía - Especializaciónspa

Archivos

Bloque original
Mostrando 1 - 4 de 4
Cargando...
Miniatura
Nombre:
Influencia de las variaciones anatómicas de la constricción apical con la edad en la exactitud de los localizadores apicales: Resultados preliminares. .pdf
Tamaño:
781.55 KB
Formato:
Adobe Portable Document Format
Descripción:
Influencia de las variaciones anatómicas de la constricción apical con la edad en la exactitud de los localizadores apicales: Resultados preliminares
No hay miniatura disponible
Nombre:
REFERENCIAS BIBLIOGRÁFICAS_ Aciego_Lan_Yelitza_2022.doc.docx
Tamaño:
16.25 KB
Formato:
Microsoft Word XML
Descripción:
Referencias bibliográficas
No hay miniatura disponible
Nombre:
CARTA AUTORIZACION DIVULGACION REPOSITORIO_ Aciego_Lan_Yelitza_2022-combinado.pdf
Tamaño:
555.98 KB
Formato:
Adobe Portable Document Format
Descripción:
Carta de autorización
No hay miniatura disponible
Nombre:
ACTA- TRABAJO DE GRADO_Aciego_Lan_Yelitza_2022.pdf
Tamaño:
262.77 KB
Formato:
Adobe Portable Document Format
Descripción:
Probatus
Bloque de licencias
Mostrando 1 - 1 de 1
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.95 KB
Formato:
Item-specific license agreed upon to submission
Descripción: