Incidencia de trombosis de stents coronarios en el «mundo real»

Resumen

ANTECEDENTES: la evidencia disponible de stents liberadores de medicamento proviene de estudios controlados con estrictos criterios de inclusión, limitando sus conclusiones y haciendo difícil la aplicación de sus resultados en el mundo real. OBJETIVO: determinar la incidencia de trombosis de stents liberadores y no liberadores de medicamento en pacientes del «mundo real». METODOLOGÍA: estudio de incidencia para determinar el número de casos de trombosis de stents implantados, mediante información obtenida a partir de historias clínicas, bases de datos y seguimiento clínico, y con base en características demográficas, factores de riesgo, consumo de clopidogrel y casos de trombosis del stent con un seguimiento de cero días a un año. RESULTADOS: 640 stents implantados (69,2% no medicados, 30,8% medicados de los cuales 18,9% eran medicados con placlitaxel y 11,9% medicados con sirolimus). Se identificaron doce eventos de trombosis (siete stents medicados y cinco no medicados). La incidencia de trombosis con cualquier tipo de stent fue de 1,88% (IC 95% 0,97-3,28). La incidencia de trombosis con stent medicado fue 3,55% (IC 95% 1,43-7,32), y con stent no medicado 1,13% (IC 95% 0,37-2,64) p=0,000. El riesgo relativo de trombosis con stent medicado es de 3,14 (IC 95% 1,01-9,78) p=0,037. El riesgo relativo de presentar trombosis con stent medicado en infarto agudo del miocardio es 8,11 (IC 95% 2,32-28,31) p=0,001. CONCLUSIONES: la incidencia de trombosis del stent aumenta en el mundo real, y existe mayor riesgo de trombosis de stents medicados especialmente cuando son implantados en el contexto de un infarto agudo del miocardio. Es necesario realizar estudios futuros que involucren una población de pacientes más amplia y con seguimiento a largo plazo.

Descripción

Abstract

BACKGROUND: The existing evidence of drug-eluting stents comes from controlled studies done with strict inclusion criteria, limiting their conclusions and making difficult to apply their findings in the real world. Objectives: determine the incidence of thrombosis between bare metal stents versus drug-eluting stents in patients in the «real world». METHODS: incidence study to determine the number of cases of thrombosis in implanted stents through information gathered from clinical records, data bases and clinical follow-up, based on demographic characteristics, risk factors, clopidogrel treatment and events of stent thrombosis with a 0 days to 1 year follow-up. RESULTS: 640 stents were implanted. 69.2% were bare metal stents and 30.8% drug-eluting stents, from which 18.9% were with placlitaxel and 11.9% with sirolimus. 12 thrombosis events were identified (7 with drug-eluting stents and 5 with bare metal stents). The incidence of thrombosis with any kind of stent was 1.88 %( CI 95% 0.97-3.28). The incidence of thrombosis with drug-eluting stents was 3.55% (CI 95%1.43-7.32), and with bare metal stents 1.13% (CI 95% 0.37-2.64) p=0.000. The relative risk of thrombosis with drug eluting stents is 3.14 (CI 95%1.01-9.78) p=0.037. The relative risk of thrombosis with drug eluting stents and acute myocardial infarction is 8.11 (CI 95%2.32-28.31) p=0,001. CONCLUSIONS: there is an increased incidence of thrombosis of coronary stents in the real world and a greater risk of thrombosis with drug eluting stents, especially when implanted in the context of an acute myocardial infarction. It is necessary to conduct further studies that may involve a higher sample of patients population and long-term follow-up.

Palabras clave

Trombosis, Stents, Cardiología intervencionista

Keywords

Thrombosis, Stents, Interventional cardiology

Temáticas

Enfermedades vasculares
Prótesis e implantes
Catéteres

Citación

Colecciones