dc.description.abstractAntecedentes: La base de titanio es un elemento intermedio que une el implante osteointegrado y el elemento protésico en una restauración implanto-soportada. Se ha observado que existen factores que pueden determinar el comportamiento mecánico de la restauración sobre ésta, particularmente en restauraciones unitarias. Sin embargo, los estudios al respecto son escasos Objetivo Establecer el comportamiento mecánico de las restauraciones unitarias implantosoportadas que utilizan bases de titanio, basándose en pruebas científicas. Método: Para el desarrollo de esta revisión temática con fines de investigación., se estableció una pregunta para guiar la revisión: ¿Cuál es el nivel de desarrollo del comportamiento mecánico de las restauraciones unitarias implantosoportadas con bases de titanio? A partir de esta pregunta, se establecieron dos puntos temáticos para esta revisión y se crearon estrategias de búsqueda para cada uno de ellos en la base de datos PubMed. Se eligieron artículos científicos sin restricciones de idioma que abordaran los objetivos de la revisión. Los datos de cada artículo seleccionado se extrajeron utilizando registros bibliográficos con criterios de extracción precisos prestablecidos. Los dos puntos temáticos fueron|1). Comportamiento mecánico in vitro de restauraciones sobre implantes unitarios utilizando bases de titanio, cuáles son sus factores determinantes y cuáles son los parámetros de evaluación, 2) Comportamiento mecánico in vivo de restauraciones sobre implantes unitarios utilizando bases de titanio, cuáles son sus factores determinantes y cuáles son los parámetros de evaluación. Resultados: Para el 1er tema se identificaron 49 publicaciones, de las que se eligieron 10 y para el 2º tema se identificaron 11 publicaciones, de las que se eligieron 6. Para la extracción de datos, se usaron fichas bibliográficas, una por cada artículo seleccionado, teniendo en cuenta los criterios de extracción de datos mencionados. Conclusiones. Las bases de titanio son una buena alternativa para la rehabilitación ya que permite una mejor disipación de cargas, al igual que podría aumentar la resistencia a la fractura de las restauraciones. En cuanto al tipo de material indicado para realizar estas coronas sobre implante podría ser el disilicato de litio o el zirconio, ya que brindan una buena estabilidad mecánica cuando se utiliza en un estado monolítico; pero el tipo de corona que brinda mayor estabilidad sobre una base de titanio es la corona de una pieza cementada y de óxido de circonio. Las complicaciones más comunes que se presentaron fue la descementación de la corona y el aflojamiento y/o fractura del tornillo.spa
dc.description.abstractenglishBackground: A titanium base is an intermediate element between an implant and a prosthesis, which may be screwed or cemented and mechanical behaviour is improved. However, it has been observed that factors such as materials, crown type, restoration type and dimensions may determine said behaviour, especially on single-tooth units. Thus, it is important to establish a clear conceptual base in order to study and define the best parameters for mechanical stability. Objective: base on scientific evidence, to establish the mechanical behaviour of single-tooth restorations supported by implants using titanium bases. Method: The present is a research-aimed thematic review on the development level of mechanical behaviour of said restorations, with two review topics and search strategy in Pubmed. The articles selected did not have language restriction, data was extracted with precise criteria such as country of origin, objective, type of study, evaluated factors, effects of such, mechanical behaviour, method, statistics used, results and conclusions from which a final review following EASE will be developed. The topics were in vitro mechanical behaviour of said implants and in vivo mechanical behaviour. Results: There were 49 publications for the first topic, from which ten were selected,11 for the second, from which six were selected and individual bibliographic files were used for article data extraction. Conclusions: Titanium bases are a good alternative since they allow better load displacement and could increase resistance to fracture. The indicated material for these could be lithium disilicate or lithium zirconium due to good stability when used monolithically, but the most stable crown type on a titanium base is cemented zirconium oxide. The most common complications were crown de-cementation and loosening or fracture of the screw.eng
dc.description.degreelevelEspecializaciónspa
dc.description.degreenameEspecialista en prostodonciaspa
dc.description.sponsorshipGrupo de Investigación UNIECLO Unidad de Investigación en Epidemiologia Clínica Oralspa
dc.format.mimetypeapplication/pdf
dc.identifier.instnameinstname:Universidad El Bosquespa
dc.identifier.reponamereponame:Repositorio Institucional Universidad El Bosquespa
dc.identifier.repourlrepourl:https://repositorio.unbosque.edu.co
dc.identifier.urihttps://hdl.handle.net/20.500.12495/11271
dc.language.isospa
dc.publisher.facultyFacultad de Odontologíaspa
dc.publisher.grantorUniversidad El Bosquespa
dc.publisher.programEspecialización en prostodonciaspa
dc.rightsAtribución-NoComercial-CompartirIgual 4.0 Internacional*
dc.rights.accessrightshttps://purl.org/coar/access_right/c_abf2
dc.rights.accessrightsinfo:eu-repo/semantics/openAccess
dc.rights.localAcceso abiertospa
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/*
dc.subjectBase de titaniospa
dc.subjectImplante unitariospa
dc.subjectComportamiento mecánicospa
dc.subjectRevisión temáticaspa
dc.subjectBase de Tispa
dc.subject.keywordsTitanium baseeng
dc.subject.keywordsBase of Tieng
dc.subject.keywordsSingle implanteng
dc.subject.keywordsMechanical behavioureng
dc.subject.keywordsThematic revieweng
dc.subject.nlmWU 500
dc.titleComportamiento mecánico de las restauraciones sobre implantes de diente único usando bases de titanio - Estado de la técnica desde la evidencia científicaspa
dc.title.translatedMechanical Behaviour of restorations on single – tooth implants using a titanium base. State – of – the art technique from scientific evidenceeng
dc.type.coarhttps://purl.org/coar/resource_type/c_7a1f
dc.type.coarversionhttps://purl.org/coar/version/c_970fb48d4fbd8a85
dc.type.driverinfo:eu-repo/semantics/bachelorThesis
dc.type.hasversioninfo:eu-repo/semantics/acceptedVersion
dc.type.localTesis/Trabajo de grado - Monografía - Especializaciónspa

Archivos

Bloque original
Mostrando 1 - 2 de 2
Cargando...
Miniatura
Nombre:
Comportamiento mecánico de las restauraciones sobre implantes de diente único usando bases de titanio
Tamaño:
1.82 MB
Formato:
Adobe Portable Document Format
Descripción:
Comportamiento mecánico de las restauraciones sobre implantes de diente único usando bases de titanio
No hay miniatura disponible
Nombre:
Referencias bibliográficas
Tamaño:
17.55 KB
Formato:
Microsoft Word XML
Descripción:
Referencias bibliográficas
Bloque de licencias
Mostrando 1 - 4 de 4
No hay miniatura disponible
Nombre:
license.txt
Tamaño:
1.95 KB
Formato:
Item-specific license agreed upon to submission
Descripción:
No hay miniatura disponible
Nombre:
Carta.pdf
Tamaño:
1.05 MB
Formato:
Adobe Portable Document Format
Descripción:
Carta de autorización
No hay miniatura disponible
Nombre:
Carta2.pdf
Tamaño:
990.74 KB
Formato:
Adobe Portable Document Format
Descripción:
Anexo
No hay miniatura disponible
Nombre:
Acta.pdf
Tamaño:
138.4 KB
Formato:
Adobe Portable Document Format
Descripción:
Acta